Input Monitor Function Select [7f0801]
View all TASCAM DA-6400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
TASCAM DA-6400/DA-6400dp TELNET protocol specifications INPUT MONITOR FUNCTION RETURN This is a return command in response to an "INPUT MONITOR FUNCTION SELECT [7F0801]" command. This returns the input monitoring function settings for all channels. Command FF Category Code 08 Sub Command 81 Machine ID 0 Parameter 68 bytes Meaning Notes Data 5 Data 6 Data 7 Always "0100" Start channel number From channel 1 Data 8 Data 9 Channel 1 monitoring function setting ・ ・ 0 = off/1 = on ・ Data72 Channel 64 monitoring function setting Request/Preset INPUT MONITOR FUNCTION SELECT [7F0801] BIT LENGTH RETURN This is a return command in response to a "BIT LENGTH SELECT [7F0822]" command. This returns the bit length setting. Command FF Category Code 08 Sub Command A2 Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 1 6 16bit Create audio files with a 16-bit setting 2 4 24bit Create audio files with a 24-bit setting Request/Preset BIT LENGTH SELECT [7F0822] MAX FILE SIZE RETURN This is a return command in response to a "MAX FILE SIZE SELECT [7F0823]" command. This returns the maximum file size setting. Command FF Category Code 08 Sub Command A3 Machine ID 0 Parameter 6 bytes Data 5/6 Data 7 Data 8 Data 9 Data10 Meaning Notes 4 0 0 6 640MB 00 2 4 1 0 1GB Capacity (MB) 4 8 2 0 2GB 01 Minute Minute Minute Minute thousa tens ones hundre nds digit digit ds digit digit Time (minutes): 240 minutes maximum Examples: "0100" is 1 minute 4002: 240 minutes Request/Preset MAX FILE SIZE SELECT [7F0823] 58 TEAC Corporation