TASCAM DA-6400 TELNET protocol specifications - Page 58

Input Monitor Function Select [7f0801]

Page 58 highlights

TASCAM DA-6400/DA-6400dp TELNET protocol specifications INPUT MONITOR FUNCTION RETURN This is a return command in response to an "INPUT MONITOR FUNCTION SELECT [7F0801]" command. This returns the input monitoring function settings for all channels. Command FF Category Code 08 Sub Command 81 Machine ID 0 Parameter 68 bytes Meaning Notes Data 5 Data 6 Data 7 Always "0100" Start channel number From channel 1 Data 8 Data 9 Channel 1 monitoring function setting ・ ・ 0 = off/1 = on ・ Data72 Channel 64 monitoring function setting Request/Preset INPUT MONITOR FUNCTION SELECT [7F0801] BIT LENGTH RETURN This is a return command in response to a "BIT LENGTH SELECT [7F0822]" command. This returns the bit length setting. Command FF Category Code 08 Sub Command A2 Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 1 6 16bit Create audio files with a 16-bit setting 2 4 24bit Create audio files with a 24-bit setting Request/Preset BIT LENGTH SELECT [7F0822] MAX FILE SIZE RETURN This is a return command in response to a "MAX FILE SIZE SELECT [7F0823]" command. This returns the maximum file size setting. Command FF Category Code 08 Sub Command A3 Machine ID 0 Parameter 6 bytes Data 5/6 Data 7 Data 8 Data 9 Data10 Meaning Notes 4 0 0 6 640MB 00 2 4 1 0 1GB Capacity (MB) 4 8 2 0 2GB 01 Minute Minute Minute Minute thousa tens ones hundre nds digit digit ds digit digit Time (minutes): 240 minutes maximum Examples: "0100" is 1 minute 4002: 240 minutes Request/Preset MAX FILE SIZE SELECT [7F0823] 58 TEAC Corporation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

TASCAM DA-6400/DA-6400dp TELNET protocol specifications
58
TEAC Corporation
INPUT MONITOR FUNCTION RETURN
This is a return command in response to an "INPUT MONITOR FUNCTION SELECT [7F0801]" command.
This returns the input monitoring function settings for all channels.
Command
FF
Category Code
08
Sub Command
81
Machine ID
0
Parameter
68 bytes
Meaning
Notes
Data 5
Always "0100"
Start channel number
From channel 1
Data 6
Data 7
Data 8
Data 9
Channel
1
monitoring
function
setting
0 = off/1 = on
Data72
Channel 64 monitoring function
setting
Request/Preset
INPUT MONITOR FUNCTION SELECT [7F0801]
BIT LENGTH RETURN
This is a return command in response to a "BIT LENGTH SELECT [7F0822]" command.
This returns the bit length setting.
Command
FF
Category Code
08
Sub Command
A2
Machine ID
0
Parameter
2 bytes
Data 5
Data 6
Meaning
Notes
1
6
16bit
Create audio files with a 16-bit setting
2
4
24bit
Create audio files with a 24-bit setting
Request/Preset
BIT LENGTH SELECT [7F0822]
MAX FILE SIZE RETURN
This is a return command in response to a "MAX FILE SIZE SELECT [7F0823]" command.
This returns the maximum file size setting.
Command
FF
Category Code
08
Sub Command
A3
Machine ID
0
Parameter
6 bytes
Data 5/6
Data 7
Data 8
Data 9
Data10
Meaning
Notes
00
4
0
0
6
640MB
Capacity (MB)
2
4
1
0
1GB
4
8
2
0
2GB
01
Minute
tens
digit
Minute
ones
digit
Minute
thousa
nds
digit
Minute
hundre
ds digit
Time (minutes): 240 minutes maximum
Examples: "0100" is 1 minute
4002: 240 minutes
Request/Preset
MAX FILE SIZE SELECT [7F0823]