TASCAM DA-6400 TELNET protocol specifications - Page 64
Input Routing Select [7f1250]
![]() |
View all TASCAM DA-6400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
TASCAM DA-6400/DA-6400dp TELNET protocol specifications INPUT ROUTING RETURN This is a return command in response to an "INPUT ROUTING SELECT [7F1250]" command. This returns the input settings for all channels Command FF Category Code 12 Sub Command D0 Machine ID 0 Parameter 260 bytes Meaning Notes Data 5 Data 6 Data 7 Always "0100" Start channel number From channel 1 Data 8 Data 9 Source channel number tens digit Data10 Source channel number ones digit Channel 1 information Data11 Source slot number Data12 Source channel hundreds digit number ・ ・ ・ Data261 Source channel number tens digit Data262 Source channel number ones digit Channel 64 information Data263 Source slot number Data264 Source channel number hundreds digit Request/Preset INPUT ROUTING SELECT [7F1250] 64 TEAC Corporation