TASCAM DA-6400 TELNET protocol specifications - Page 24

specify

Page 24 highlights

TASCAM DA-6400/DA-6400dp TELNET protocol specifications PROJECT SKIP This changes the project. If the current project is the last project, specifying "00" will move to the first project. If the current project is the first project, specifying "01" will move to the last project. Command 7F Category Code 02 Sub Command 1A Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 0 0 Project next Move to the next project 0 1 Project previous Move to the project one before the current project. ・ If the unit receives any Data other than the above, it will send ILLEGAL [F2]. Return none PROJECT SELECT Specify the project number to change the current project. Command 7F Category Code 02 Sub Command 23 Machine ID 0 Parameter 8 bytes Meaning Notes Data 5 Data 6 Data 7 0000 Fixed value: specify "0000" Data 8 Data 9 Project number tens digit Data 10 Project number ones digit Data 11 Project number thousands Project number digit Example: "5400" is project 54 Data 12 Project number hundreds digit ・ If a number is specified for a project that does not exist on the media, the unit will return ILLEGAL [F2]. ・ If the current project number is specified, the unit will return ILLEGAL [F2]. Return none 24 TEAC Corporation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

TASCAM DA-6400/DA-6400dp TELNET protocol specifications
24
TEAC Corporation
PROJECT SKIP
This changes the project.
If the current project is the last project, specifying "00" will move to the first project.
If the current project is the first project, specifying "01" will move to the last project.
Command
7F
Category Code
02
Sub Command
1A
Machine ID
0
Parameter
2 bytes
Data 5
Data 6
Meaning
Notes
0
0
Project next
Move to the next project
0
1
Project previous
Move to the project one before the current project.
If the unit receives any Data other than the above, it will send ILLEGAL [F2].
Return
none
PROJECT SELECT
Specify the project number to change the current project.
Command
7F
Category Code
02
Sub Command
23
Machine ID
0
Parameter
8 bytes
Meaning
Notes
Data 5
0000
Fixed value:
specify
“0000”
Data 6
Data 7
Data 8
Data 9
Project number tens digit
Project number
Example: "5400" is project 54
Data 10
Project number ones digit
Data 11
Project number thousands
digit
Data 12
Project number hundreds
digit
If a number is specified for a project that does not exist on the media, the unit will return ILLEGAL [F2].
If the current project number is specified, the unit will return ILLEGAL [F2].
Return
none