TASCAM DA-6400 TELNET protocol specifications - Page 24
specify
View all TASCAM DA-6400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
TASCAM DA-6400/DA-6400dp TELNET protocol specifications PROJECT SKIP This changes the project. If the current project is the last project, specifying "00" will move to the first project. If the current project is the first project, specifying "01" will move to the last project. Command 7F Category Code 02 Sub Command 1A Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 0 0 Project next Move to the next project 0 1 Project previous Move to the project one before the current project. ・ If the unit receives any Data other than the above, it will send ILLEGAL [F2]. Return none PROJECT SELECT Specify the project number to change the current project. Command 7F Category Code 02 Sub Command 23 Machine ID 0 Parameter 8 bytes Meaning Notes Data 5 Data 6 Data 7 0000 Fixed value: specify "0000" Data 8 Data 9 Project number tens digit Data 10 Project number ones digit Data 11 Project number thousands Project number digit Example: "5400" is project 54 Data 12 Project number hundreds digit ・ If a number is specified for a project that does not exist on the media, the unit will return ILLEGAL [F2]. ・ If the current project number is specified, the unit will return ILLEGAL [F2]. Return none 24 TEAC Corporation