TASCAM DA-6400 TELNET protocol specifications - Page 37

Input Monitor Function Return [ff0881]

Page 37 highlights

TASCAM DA-6400/DA-6400dp TELNET protocol specifications INPUT MONITOR FUNCTION SELECT This turns the input monitoring function of the controlled device on/off. This turns the input monitoring function on/off for the channel number specified by Data 5-8. If 0 is specified for the channel number, the input monitoring function setting for all channels can be specified with Data 9. If 0 is specified for the channel number, set only Data 9. If 0 is specified for the channel number and settings are made for Data 10 and on, the unit will return ILLEGAL [F2]. A return command is only sent when Sense [FF] is specified for Data 5 and Data 6. Command 7F Category Code 08 Sub Command 01 Machine ID 0 Parameter 5-68 bytes Meaning Notes Data 5 Start channel number tens digit Data 6 Data 7 Data 8 Start channel number ones digit Start channel number thousands digit Start channel number hundreds Start channel number Example: "6400" is channel 64 0000: all channels digit Data 9 ・ ・ Monitor function settings ・ 0 = off/1 = on If 0 is specified as the start channel, use only Data 9 Data72 ・ If the unit receives any Data set outside the range, it will send ILLEGAL [F2]. Return INPUT MONITOR FUNCTION RETURN [FF0881] 37 TEAC Corporation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

TASCAM DA-6400/DA-6400dp TELNET protocol specifications
37
TEAC Corporation
INPUT MONITOR FUNCTION SELECT
This turns the input monitoring function of the controlled device on/off.
This turns the input monitoring function on/off for the channel number specified by Data 5
8.
If 0 is specified for the channel number, the input monitoring function setting for all channels can be specified
with Data 9.
If 0 is specified for the channel number, set only Data 9.
If 0 is specified for the channel number and settings are made for Data 10 and on, the unit will return ILLEGAL
[F2].
A return command is only sent when Sense [FF] is specified for Data 5 and Data 6.
Command
7F
Category Code
08
Sub Command
01
Machine ID
0
Parameter
5-68 bytes
Meaning
Notes
Data 5
Start channel
number tens digit
Start channel number
Example: "6400" is channel 64
0000: all channels
Data 6
Start channel
number ones digit
Data 7
Start channel
number thousands
digit
Data 8
Start channel
number hundreds
digit
Data 9
Monitor function settings
0 = off/1 = on
If 0 is specified as the start channel, use only Data 9
Data72
If the unit receives any Data set outside the range, it will send ILLEGAL [F2].
Return
INPUT MONITOR FUNCTION RETURN [FF0881]