TASCAM DA-6400 TELNET protocol specifications - Page 46

Meter Peak Hold Time Preset, Meter Peak Clear

Page 46 highlights

TASCAM DA-6400/DA-6400dp TELNET protocol specifications METER PEAK HOLD TIME PRESET This sets the METER PEAK HOLD TIME used by the controlled device. A return command is only sent when Sense [FF] is specified. Command 7F Category Code 13 Sub Command 21 Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 0 0 Hold Time 0s No peak hold ・ ・ 01-09: peak hold for this number of seconds ・ 1 0 Hold Time 10s Hold for 10 seconds F E Hold Time Inf. Hold until cleared F F Sense This requests that the preset contents be returned. ・ If the unit receives any Data other than the above, it will send ILLEGAL [F2]. Return METER PEAK HOLD TIME RETURN [FF13A1] METER PEAK CLEAR Clear meter peak holds on the controlled device. Command 7F Category Code 13 Sub Command 30 Machine ID 0 Parameter none Return none 46 TEAC Corporation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

TASCAM DA-6400/DA-6400dp TELNET protocol specifications
46
TEAC Corporation
METER PEAK HOLD TIME PRESET
This sets the METER PEAK HOLD TIME used by the controlled device.
A return command is only sent when Sense [FF] is specified.
Command
7F
Category Code
13
Sub Command
21
Machine ID
0
Parameter
2 bytes
Data 5
Data 6
Meaning
Notes
0
0
Hold Time 0s
No peak hold
01
09: peak hold for this number of seconds
1
0
Hold Time 10s
Hold for 10 seconds
F
E
Hold Time Inf.
Hold until cleared
F
F
Sense
This requests that the preset contents be returned.
If the unit receives any Data other than the above, it will send ILLEGAL [F2].
Return
METER PEAK HOLD TIME RETURN [FF13A1]
METER PEAK CLEAR
Clear meter peak holds on the controlled device.
Command
7F
Category Code
13
Sub Command
30
Machine ID
0
Parameter
none
Return
none