Xerox 4540 Service Manual - Page 151

To Replace a Hard Drive (CRU), Replace the disk drives access cover

Page 151 highlights

11. Replace the disk drives access cover and, using a No. 1 Phillips screwdriver, tighten the two screws on the left and right sides. See Section t, "To Remove the Drives Access Cover" on page 3-13. ▼ To Replace a Hard Drive (CRU) This section describes how to remove and replace a drive. It is a good practice to allocate five drives (roughly 10 percent of the total capacity) as hot spares. Note - This component is a hot-pluggable CRU and can be replaced by anyone. Hot-pluggable means that the disk drive must be first brought offline by using a management software or operating system command; however, the server does not need to be powered off. The system designation of the drives is shown on the service label. TABLE 3-10 lists the qualified part numbers for this component. These part numbers are subject to change over time. Note - Do not mix drives of different drive capacities. For an updated list of components, see the following web site: http://sunsolve.sun.com/handbook_pub/Systems/ TABLE 3-10 Hard Drives for the X4500 Server Disk Drive Seagate 250GB SATA 3.5" drive (X4500) Hitachi 500GB, SATA, 3.5" drive (X4500, X4540) Hitachi 750GB, SATA, 3.5" drive (X4500, migrated X4540*) Hitachi 1-TB , SATA 3.5" drive (X4500, X4540) Part Number #541-1468, XRA-ST1CH-250G7KZ (X-option) #541-3050, XRA-ST1CH-500G7KZ (X-option) #540-7244, XRA-ST1CH-750G7KZ (X-option) #540-7507, XRA-ST1CH-1T7K (X-option) Chapter 3 Maintaining the Sun Fire X4500 and X4540 Servers 3-31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264

Chapter 3
Maintaining the Sun Fire X4500 and X4540 Servers
3-31
11. Replace the disk drives access cover and, using a No. 1 Phillips screwdriver,
tighten the two screws on the left and right sides. See
Section t, “To Remove the
Drives Access Cover” on page 3-13
.
To Replace a Hard Drive (CRU)
This section describes how to remove and replace a drive. It is a good practice to
allocate five drives (roughly 10 percent of the total capacity) as hot spares.
Note –
This component is a hot-pluggable CRU and can be replaced by anyone.
Hot-pluggable means that the disk drive must be first brought offline by using a
management software or operating system command; however, the server does not
need to be powered off.
The system designation of the drives is shown on the service label.
TABLE 3-10
lists the qualified part numbers for this component. These part numbers
are subject to change over time.
Note –
Do not mix drives of different drive capacities.
For an updated list of components, see the following web site:
TABLE 3-10
Hard Drives for the X4500 Server
Disk Drive
Part Number
Seagate 250GB SATA 3.5” drive (X4500)
#541-1468,
XRA-ST1CH-250G7KZ (X-option)
Hitachi 500GB, SATA, 3.5” drive (X4500, X4540)
#541-3050,
XRA-ST1CH-500G7KZ (X-option)
Hitachi 750GB, SATA, 3.5” drive (X4500, migrated
X4540*)
#540-7244,
XRA-ST1CH-750G7KZ (X-option)
Hitachi 1-TB , SATA 3.5" drive (X4500, X4540)
#540-7507,
XRA-ST1CH-1T7K (X-option)