3.9.4.1 SSD Restrictions The following are important restrictions when using SSDs: ■ Do not mix SSDs of different manufacturers. ■ Do not mix drives of the same manufacturer with different drive capacities. ■ SSDs are not to be installed in the boot drive slots. TABLE 2 SSD Locations Supported by Sun Fire X4540 Controller Controller Controller Controller Controller Controller 0 1 2 3 4 5 3 7 11 15 19 23 27 31 35 39 43 47 2 6 10 14 18 22 26 30 34 38 42 46 1* 5 9* 13 17 21 25 29 33 37 41 45 0* 4 8* 12 16 20 24 28 32 36 40 44 Fan Trays (front of system) * - Boot disk slot. Do not install SSD. Note - For an updated list of components, see the following web site: http://sunsolve.sun.com/handbook_pub/Systems/ ▼ To Replace an SSD Note - Before removing a drive, have the replacement drive ready to be installed. Use this procedure to remove a drive prior to installing an SSD. This procedure applies to hard drives and SSDs. 1. Remove the drives access cover. See "To Remove the Drives Access Cover" on page 3-13. 2. Identify the drive to be removed by checking its LEDs. If the middle LED is on (amber), the drive is faulty and should be replaced. 3-36 Sun Fire X4500/X4540 Server Service Manual • May 2010