Xerox 4540 Service Manual - Page 251
I2E Bus Devices, F.1 Power-On Reset Sequence, F.2 I2E Bus Address Table
View all Xerox 4540 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 251 highlights
F A P P E N D I X I2E Bus Devices This appendix describes the I2E bus devices. F.1 Power-On Reset Sequence The Inter-IC Communication bus (I2C) is a simple 2-pin serial bus used to control some of the basic chassis management features. These include existing EEPROMs, fan controllers, and power supply monitors that are used to monitor the health and status of the chassis. In some instances, such as temperature, a separate interrupt immediately alerts the processors when it detects a problem. F.2 I2E Bus Address Table TABLE F-1 shows the addresses of the devices on the bus. TABLE F-1 I2E Bus Addresses Description Part # Fan controller 0 VSC055-01 Fan controller 1 VSC055-01 System monitor ADM1026 Processor inlet temp LM75 sensor PCI card area temp LM75 sensor Location Disk backplane Disk backplane Front of I/O controller Rear of CPU board Address (Hex) 0x1000000 (40/80) 0x1000001 (41/82) 0x0101100 (2C/58) 0x1001001 (49/92) Between PCI slots on I/O 0x1001010 (4A/94) controller F-1