HP DL760 ProLiant DL760 Generation 2 Server Maintenance and Service Guide - Page 103

For More Information, HP Servers, Troubleshooting Guide - proliant g2 documentation

Page 103 highlights

Diagnostic Tools Table 7-1: Diagnostic Tools continued Tool What it is Array Diagnostics Utility (ADU) ADU is a Windows-based tool designed to run on all HP systems that support HP array controllers. The two main functions of ADU are: • To collect all possible information about the array controllers in the system. • To generate a list of detected problems. This tool is available for all HP servers covered by this guide. Drive Array Advanced Diagnostics (DAAD) The predecessor to ADU, DAAD is a DOS-based tool for HP servers with Smart Array Controllers. DAAD collects information about the array controllers in the system and offers a list of detected problems. Integrated Management Log (IML) IML is a log of system events, such as system failures or nonfatal error conditions. View events in the Integrated Management Log from within: • Insight Manager • Survey Utility • Operating system-specific IML utilities Power-On Self Test A diagnostic testing sequence run by the server when power is turned on. POST will determine if the server hardware components are properly working. Automatic Server Recovery (ASR-2) ASR-2 is a feature of HP Systems Health Driver. If a server failure extends beyond a set time, the system reboots and attempts to recover. How to run it Use the information provided in the ADU. For a complete list of ADU error messages, refer to the HP Servers Troubleshooting Guide. For a list of HP servers still supported by this tool, visit the HP website: www.hp.com The Integrated Management Log requires HP operating systemdependent drivers. Refer to the Support Software CD for instructions on installing the appropriate drivers. For a list of POST error messages, refer to the HP Servers Troubleshooting Guide. For More Information For detailed information about each of these diagnostic tools, refer to the HP Servers Troubleshooting Guide. For detailed information on troubleshooting the ProLiant DL760 G2 server, refer to the HP ProLiant DL760 Generation 2 Server User Guide. For detailed information about the RBSU, refer to the ROM-Based Setup Utility User Guide on the Documentation CD. 7-4 HP ProLiant DL760 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Jed Part Number: 201262-003 Last Saved On: 2/10/04 4:12 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135

Diagnostic Tools
7-4
HP ProLiant DL760 Generation 2 Server Maintenance and Service Guide
HP CONFIDENTIAL
Codename: Jed Part Number: 201262-003 Last Saved On: 2/10/04 4:12 PM
Table 7-1:
Diagnostic Tools
continued
Tool
What it is
How to run it
Array Diagnostics Utility
(ADU)
ADU is a Windows-based tool designed to
run on all HP systems that support HP
array controllers. The two main functions
of ADU are:
To collect all possible information
about the array controllers in the
system.
To generate a list of detected
problems.
This tool is available for all HP servers
covered by this guide.
Use the information provided in the
ADU.
For a complete list of ADU error
messages, refer to the
HP Servers
Troubleshooting Guide
.
Drive Array Advanced
Diagnostics (DAAD)
The predecessor to ADU, DAAD is a
DOS-based tool for HP servers with Smart
Array Controllers. DAAD collects
information about the array controllers in
the system and offers a list of detected
problems.
For a list of HP servers still supported
by this tool, visit the HP website:
www.hp.com
Integrated Management Log
(IML)
IML is a log of system events, such as
system failures or nonfatal error
conditions. View events in the Integrated
Management Log from within:
Insight Manager
Survey Utility
Operating system-specific IML utilities
The Integrated Management Log
requires HP operating system-
dependent drivers. Refer to the
Support Software CD for instructions
on installing the appropriate drivers.
Power-On Self Test
A diagnostic testing sequence run by the
server when power is turned on. POST will
determine if the server hardware
components are properly working.
For a list of POST error messages,
refer to the
HP Servers
Troubleshooting Guide
.
Automatic Server Recovery
(ASR-2)
ASR-2 is a feature of HP Systems Health
Driver. If a server failure extends beyond a
set time, the system reboots and attempts
to recover.
For More Information
For detailed information about each of these diagnostic tools, refer to the
HP Servers
Troubleshooting Guide
.
For detailed information on troubleshooting the ProLiant DL760 G2 server, refer to the
HP ProLiant DL760 Generation 2 Server User Guide.
For detailed information about the RBSU, refer to the
ROM-Based Setup Utility User Guide
on the Documentation CD.