Panasonic 98 Large Format 4K Professional Display Operating Instructions - Page 67

Early Warning Software

Page 67 highlights

Command ERST? LAMP? INST? NAME? INF1? INF2? INFO? CLSS? Control Error status query First byte: Fan error. 0 or 2. Second byte: 0 Third byte: 0 Fourth byte: 0 Fifth byte: 0 Sixth byte: Other error. 0 or 2. ● Meaning of 0, 2. 0: Error is not detected, 2: Error Lamp status query Not supported Input switch list query ● The numbers from 12 to 15 depend on the installed SLOT. 31: HDMI1 input (HDMI1) 32: HDMI2 input (HDMI2) 33: HDMI3 input (HDMI3) 34: HDMI4 input (HDMI4) 35: DisplayPort input (DisplayPort) 36: DIGITAL LINK input (DIGITAL LINK) 37: DVI-D IN input (DVI-D) 11: PC IN input (PC) When installed "3G-SDI Terminal Board with Audio" to either SLOT 1 or SLOT 2. 12: SDI1 input / SDI3 input (SDI1 / SDI3) 13: SDI2 input / SDI4 input (SDI2 / SDI4) When installed "3G-SDI Terminal Board with Audio" to both SLOT 1 and SLOT 2. 12: SDI1 input (SDI1) 13: SDI2 input (SDI2) 14: SDI3 input (SDI3) 15: SDI4 input (SDI4) Display name query The name selected in [Network settings] is returned. Manufacturer name query Returns "Panasonic". Model name query Returns "84LQ70U". (Example: 84-inch U model) Returns "84LQ70W". (Example: 84-inch W model) Other information query Returns version number. Class information query Returns "1". PJLink security authentication When using PJLink with security authorization, either of the password set for administrator privileges and the password set for user privileges with Web browser control can be used as the password for PJLink. (see page 69) When using PJLink without security authorization, set use without the password for administrator privileges and the password for user privileges of Web browser control. ● Concerning the specification of PJLink, see the web site of Japan Business Machine and Information System Industries Association (JBMIA) below: http://pjlink.jbmia.or.jp/english/index.html Early Warning Software This unit supports "Early Warning Software" which monitors the statuses of devices (projectors or flat-panel displays) connected to an intranet, reports failures of devices and gives advance warning by detecting a predicted abnormality. The maximum number of devices that can be registered to monitor differs according to the type of license. Up to 2048 devices can be registered and used for free for a maximum of 90 days after the installation to PC has completed. ● For more details, visit the following web site. http://panasonic.net/prodisplays/products/et-swa100/index.html English 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85

67
English
Command
Control
ERST?
Error status query
First byte:
Fan error. 0 or 2.
Second byte: 0
Third byte: 0
Fourth byte: 0
Fifth byte: 0
Sixth byte:
Other error. 0 or 2.
Meaning of 0, 2.
0:
Error is not detected,
2: Error
LAMP?
Lamp status query
Not supported
INST?
Input switch list query
The numbers from 12 to 15 depend
on the installed SLOT.
31: HDMI1 input (HDMI1)
32: HDMI2 input (HDMI2)
33: HDMI3 input (HDMI3)
34: HDMI4 input (HDMI4)
35:
DisplayPort input (DisplayPort)
36:
DIGITAL LINK input (DIGITAL
LINK)
37: DVI-D IN input (DVI-D)
11: PC IN input (PC)
When installed “3G-SDI Terminal Board
with Audio” to either SLOT 1 or SLOT 2.
12:
SDI1 input / SDI3 input (SDI1 /
SDI3)
13:
SDI2 input / SDI4 input (SDI2 /
SDI4)
When installed “3G-SDI Terminal Board
with Audio” to both SLOT 1 and SLOT
2.
12: SDI1 input (SDI1)
13: SDI2 input (SDI2)
14: SDI3 input (SDI3)
15: SDI4 input (SDI4)
NAME?
Display name query
The name selected in [Network
settings] is returned.
INF1?
Manufacturer name query
Returns “Panasonic”.
INF2?
Model name query
Returns “84LQ70U”.
(Example: 84-inch U model)
Returns “84LQ70W”.
(Example: 84-inch W model)
INFO?
Other information query
Returns version number.
CLSS?
Class information query
Returns “1”.
PJLink security authentication
When using PJLink with security authorization, either
of the password set for administrator privileges and
the password set for user privileges with Web browser
control can be used as the password for PJLink. (see
page 69)
When using PJLink without security authorization, set
use without the password for administrator privileges
and the password for user privileges of Web browser
control.
Concerning the specification of PJLink, see the web
site of Japan Business Machine and Information
System Industries Association (JBMIA) below:
Early Warning Software
This unit supports “Early Warning Software” which
monitors the statuses of devices (projectors or flat-panel
displays) connected to an intranet, reports failures of
devices and gives advance warning by detecting a
predicted abnormality.
The maximum number of devices that can be registered
to monitor differs according to the type of license. Up
to 2048 devices can be registered and used for free for
a maximum of 90 days after the installation to PC has
completed.
For more details, visit the following web site.