DIP Switch Setting (PS• Data), Fixed to OFF - wv cu360c n
UPC - 791871503454
View all Panasonic WVCU360C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
• Daisy Chain Connection Video Multiplexer WJ-FS309 (WJ-FS316) Data Multiplex Unit WJ-MP204C System Controller WV-CU360C DATA Termination: ON DATA Termination: OFF Branch Cable RS-485 Cable DATA Termination: ON RS-485 Cable s DIP Switch Setting (PS •Data) An 8-bit DIP switch mounted on the rear panel specifies the communication mode, etc. The default position is marked with an asterisk *. OFF ON 12 3 4 56 78 MODE Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Function OFF Data transmission mode Fixed to OFF* Baud rate selection Fixed to OFF* Operation mode Operator* Line termination Off Reserved Fixed to OFF* System Unit Version Fixed to OFF* System Unit Version Fixed to OFF* System Unit Version Fixed to OFF* SW position ON Not used Not used Administrator On* Not used Not used Not used Not used 1. Remove the DC plug from the rear of the controller. 2. Set the switch referring to the table. 3. Connect the DC plug to the controller. Notes: • Bits 1 - 4 are reserved. • Bit 5 opens or terminates the communication chain. The switch should be set to OFF when the controller is located in an intermediate position. • Bit 6 specifies the operation mode, Operator or Administrator. The switch should be set to Administrator when setting up the controller. Remember to set this switch to the right position after completion of the setup operation. • Bits 7 and 8 are used in the OFF position. 15