Panasonic WVCU360C WVCU360C User Guide - Page 19
Administrator Authorization, Baud Rate, Parity, Wait Time, Controller Unit-Group Address
UPC - 791871503454
View all Panasonic WVCU360C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
q Administrator Authorization 1. Press the CAM/SET button while [SEtUP] is displayed. The prompt appears. 2. Enter a password with the numeric buttons, then press the CAM/SET button. The default setting is [12345]. 3. [SPEED] appears when the right password is entered. If password entry failed, the menu returns to Notes: • We recommend that you register a new password different from "12345" in [SUSrP], and note down the registered password for future reference. • Powering up the controller while holding down numeric buttons 2, 4 and 5 simultaneously will reset the password to "12345". Remember that this procedure also resets all other menu parameters to the default settings. q Baud Rate In this menu, the communication speed (bps: bits per second) is selected. The communication speed should match that of the other units connected in the communication chain. 1. Display [SPEED] and press the CAM/SET button twice. 2. Select a parameter entering a bracket-enclosed number, e.g., (3), moving the joystick right and left, or pressing the [+] and [-] button. The default setting is 19 200 bps. (1) 2 400: 2 400 bps (2) 4 800: 4 800 bps (3) 9 600: 9 600 bps (4) 19 200: 19 200 bps Note: Selecting a slower rate (e.g., 2 400 bps) will delay the response time (e.g., the time until an activated alarm is reset). 3. Press the CAM/SET button to validate the selection. 4. Press the ESC button to go back to the previous menu. q Parity In this menu, the parity check mode is selected. 1. Display [PrtY] and press the CAM/SET button twice. 2. Select a parameter with the joystick. The default setting is None. n: None E: Even parity 3. Press the CAM/SET button to validate the selection. 4. Press the ESC button to go back to the previous menu. q Wait Time In this menu a wait time is selected. The controller will retransmit data when there is no response during the specified wait time. 1. Display [LJAit] and press the CAM/SET button twice. 2. Select a parameter with the joystick. The default setting is Off. (1) OFF: Off, no retransmission of data (2) 100: 100 ms (3) 200: 200 ms (4) 400: 400 ms (5) 500: 500 ms (6) 1 000: 1 s 3. Press the CAM/SET button to validate the selection. 4. Press the ESC button to go back to the previous menu. The following two menus should be maintained in the default condition. q Controller Unit-Group Address [CU-gr] appears on the Setup menu, but leave the default as it is. q System Unit-Group Address [SU-gr] appears on the Setup menu, but leave the default as it is. 19