Panasonic WVCU360C WVCU360C User Guide - Page 57

Controller Number Setting, Switch Setting Procedures, P R O G R A M, O P E R A T O R, S Y S T E M

Page 57 highlights

78 456 23 s Controller Number Setting Set this switch always to 1 when using the System Controller with the WJ-SX350. 901 CONTROLLER No. q Switch Setting Procedures Set the MODE DIP switch and CONTROLLER NO. switch as follows. 1. Remove the DC plug from the rear of the controller. 2. Set the MODE switches. Bit 1 through 3 should match the version of the WJSX350 installed in your system. Open the SETUP MENU of the WJ-SX350 and check the version shown in the upper right corner of the menu. For version 1.xx, set the switches as shown below. OFF ON 12 3 4 56 78 MODE • Bit 1 should be set to OFF*. • Bit 2 should be set to ON. • Bit 3 should be set to OFF*. Bits 4 through 8 are not version related. • Bit 4 should be set to OFF*. • Bit 5 should be set to ON*. • Bit 6 should be set to OFF* (Operator) normally, or ON (Administrator) when setting up the controller. • Bit 7 should be set to OFF*. Baud rate selection is automatic. • Bit 8 should be set to OFF* normally. 3. Connect the DC plug to the controller. SETUP MENU P R O G R A M O P E R A T O R S Y S T E M CAM DATA LOAD CAMERA TITLE CAM-POSI MAP FUNCTION KEY 6.xx/1.xx For version 6.00 or later, set the switches as shown below. OFF ON 12 3 4 56 78 MODE • Bit 1 should be set to OFF*. • Bit 2 should be set to ON. • Bit 3 should be set to ON. 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77

59
Controller Number Setting
Set this switch always to 1 when using the System
Controller with the WJ-SX350.
Switch Setting Procedures
Set the MODE DIP switch and CONTROLLER NO. switch as
follows.
1.
Remove the DC plug from the rear of the controller.
2.
Set the MODE switches.
Bit 1 through 3 should match the version of the WJ-
SX350 installed in your system. Open the SETUP MENU
of the WJ-SX350 and check the version shown in the
upper right corner of the menu.
For version 6.00 or later, set the switches as shown
below.
Bit 1 should be set to OFF*.
Bit 2 should be set to ON.
Bit 3 should be set to ON.
S E T U P
M E N U
6.xx/1.xx
P R O G R A M
O P E R A T O R
S Y S T E M
C A M
D A T A
L O A D
C A M E R A
T I T L E
C A M – P O S I
M A P
F U N C T I O N
K E Y
MODE
1
2
3
4
5
6
7
8
OFF
ON
For version 1.xx, set the switches as shown below.
Bit 1 should be set to OFF*.
Bit 2 should be set to ON.
Bit 3 should be set to OFF*.
Bits 4 through 8 are not version related.
Bit 4 should be set to OFF*.
Bit 5 should be set to ON*.
• Bit 6 should be set to OFF* (Operator) normally, or
ON (Administrator) when setting up the controller.
• Bit 7 should be set to OFF*. Baud rate selection is
automatic.
Bit 8 should be set to OFF* normally.
3.
Connect the DC plug to the controller.
MODE
1
2
3
4
5
6
7
8
OFF
ON
0
9
8
7
6
5
4
3
2
1
CONTROLLER No.