DATA Port Connection, Main CPU
UPC - 791871503454
View all Panasonic WVCU360C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
q DATA Port Connection Data ports are connected with RS-485 cables among devices using Camera Communication protocol as follows. Note: When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485 communication. • Internal Diagram No. Data Flow 1 - 1 2 Main CPU ← WV-CU360C 3 Main CPU ← WV-CU360C 4 Main CPU → WV-CU360C 6 5 Main CPU → WV-CU360C 6 - Name No. GND 1 Controller end TX(B) 2 1 TX(A) 3 RX(B) 4 RX(A) 5 6 GND 6 • Basic Connection TX (B) TX (A) RX (B) RX (A) 78 23 901 CONTROLLER No. MODE DATA DC 9V IN 78 23 901 CONTROLLER No. MODE DATA DC 9V IN 456 456 456 456 78 23 901 CONTROLLER No. MODE DATA DC 9V IN 78 23 901 CONTROLLER No. MODE DATA DC 9V IN ETHERNET SYSTEM CAMERA CONTROLLER CROSS POINT OSD PERIFERAL INTERFACE (RS-232C) 3 2 1 SYSTEM CONTROLLER (RS-485) DATA 6 DATA 5 DATA 4 DATA 3 DATA 2 DATA 1 REDUNDANT SATELLITE CPU MODE PARALLEL NO YES STANDALONE SATELLITE Main CPU Central Processing Unit SIGNAL GND 125V 3.0A AC IN 71