Panasonic WVCU360C WVCU360C User Guide - Page 44
Unit Version, Controller Number Setting, Switch Setting Procedures
UPC - 791871503454
View all Panasonic WVCU360C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
q Unit Version The unit ID is defined by the upper 3 bits depending on the software version installed in the unit. • WJ-FS616 OFF ON 12 3 4 56 78 MODE • WJ-FS616C OFF ON 12 3 4 56 78 MODE 78 456 23 s Controller Number Setting Set this switch always to 1 when using the System Controller in a system including a Multiplexer WJFS616/FS616C. 901 CONTROLLER No. q Switch Setting Procedures 1. Remove the DC plug from the rear of the controller. 2. Set the MODE switch referring to the table. • The bit switches #1 to #3 should be set to positions that match the version of the Multiplexer installed in the system. • Bit 5 opens or terminates the communication chain. The switch should be set to OFF when the controller is located in an intermediate position of the chain. • Bit 6 specifies either Operator or Administrator as the operation mode. Set to Administrator when setting up the controller. • Bits 4, 7 and 8 are reserved. 3. Set the CONTROLLER NO. switch to 1. 4. Connect the DC plug to the controller. 45