Sony BVME170A User Manual (Operating Instructions - BVM-E250A / BVM-E170A) - Page 82

Error Notify Clear, Audio Level Meter

Page 82 highlights

Chapter 3 Menu Network Menu SDCP Port No SDAP Port No SDAP Broadcast SDAP Broadcast Period Acceptable IP Address Reset Protocol Setting Parallel Remote Parallel Remote 1 Pin to 8 Pin Function and operation ([ ]: factory setting) Sets the SDCP port number. Set to 53434 to 53534. [53484] Sets the SDAP port number. Set to 53812 to 53912. [53862] Sets whether or not to issue the SDAP (Disable or [Enable]). Sets the period (seconds) to issue the SDAP. Set to 05 to 30. [15] Sets the IP address to connect. When the item is selected, you can set IP1 to IP4. Cancel: Cancels the changed or confirmed setting. Confirm: Saves the changed or confirmed setting. Resets the protocol setting. When the item is selected, the following message appears. Are you sure? OK: To reset data, press the ENTER (Ent) button. Cancel: To cancel, press the MENU button. Sets the parallel remote function. Selects whether or not to use the parallel remote functions. ([Off] or On) Assigns the function to each pin of the PARALLEL REMOTE connector when Parallel Remote is set to On. The default assignment of functions is as follows: 1 Pin: [CH01] 2 Pin: [CH02] 3 Pin: [External Sync] 4 Pin: [Mono] 5 Pin: [Marker] 6 Pin: [unused] 7 Pin: [unused] 8 Pin: [Tally] You can change the assignment to the following functions for pins 1 to 8. The functions shown with item name only are the same as those assigned to the function buttons on the controller. For details on these functions, see "Function Key" (page 92) of the Controller menu. Parallel Remote (1/5) CH01 to 30: Selects a channel number. Enter the desired channel number with the numeric buttons. ----: Unused Under Scan,1) Over Scan,1) Native Scan, 16:9, H Delay, V Delay, External Sync, Comb 1) The scan mode is set to Normal Scan when Under Scan or Over Scan is off. Parallel Remote (2/5) Aperture, Mono, Blue Only, R Off, G Off, B Off, Chroma Up, Interlace Tally: The function to turn on the tally lamp Power Off: The monitor power function Parallel Remote (3/5) Marker, Aspect Marker, Area Marker 1, Area Marker 2, Center Marker, Aspect Marker-Line, Aspect Blanking-Half, Aspect Blanking-Black Parallel Remote (4/5) Side by Side, Wipe, Butterfly, Blending, Error Notify Clear, Audio Level Meter, ALM Hold Reset, Time Code Parallel Remote (5/5) Difference, Checkerboard, L/R Switch, Horopter Check, Flip H For the pin assignment, see "PARALLEL REMOTE connector" in Location and Function of Parts on page 17 (BVM-E250A) or page 20 (BVM-E170A). 82 System Configuration Menu

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155

82
System Configuration Menu
Chapter 3
Menu
Network
SDCP Port No
Sets the SDCP port number.
Set to
53434
to
53534
.
[53484]
SDAP Port No
Sets the SDAP port number.
Set to
53812
to
53912
.
[53862]
SDAP Broadcast
Sets whether or not to issue the SDAP (
Disable
or
[Enable]
).
SDAP Broadcast Period
Sets the period (seconds) to issue the SDAP.
Set to
05
to
30
.
[15]
Acceptable IP Address
Sets the IP address to connect.
When the item is selected, you can set
IP1
to
IP4
.
Cancel:
Cancels the changed or confirmed setting.
Confirm:
Saves the changed or confirmed setting.
Reset Protocol Setting
Resets the protocol setting.
When the item is selected, the following message appears.
Are you sure?
OK:
To reset data, press the ENTER (Ent) button.
Cancel:
To cancel, press the MENU button.
Parallel Remote
Sets the parallel remote function.
Parallel Remote
Selects whether or not to use the parallel remote functions.
(
[Off]
or
On
)
1 Pin to 8 Pin
Assigns the function to each pin of the PARALLEL REMOTE connector when Parallel Remote
is set to On.
The default assignment of functions is as follows:
1 Pin:
[CH01]
2 Pin:
[CH02]
3 Pin:
[External Sync]
4 Pin:
[Mono]
5 Pin:
[Marker]
6 Pin:
[unused]
7 Pin:
[unused]
8 Pin:
[Tally]
You can change the assignment to the following functions for pins 1 to 8.
The functions shown with item name only are the same as those assigned to the function
buttons on the controller.
For details on these functions, see “Function Key” (page 92) of the Controller menu.
Parallel Remote (1/5)
CH01 to 30:
Selects a channel number.
Enter the desired channel number with the
numeric buttons.
----:
Unused
Under Scan
,
1)
Over Scan
,
1)
Native Scan
,
16:9
,
H Delay
,
V Delay
,
External Sync
,
Comb
1) The scan mode is set to Normal Scan when Under Scan or Over Scan is off.
Parallel Remote (2/5)
Aperture
,
Mono
,
Blue Only
,
R Off
,
G Off
,
B Off
,
Chroma Up
,
Interlace
Tally:
The function to turn on the tally lamp
Power Off:
The monitor power function
Parallel Remote (3/5)
Marker
,
Aspect Marker
,
Area Marker 1
,
Area Marker 2
,
Center Marker
,
Aspect
Marker-Line
,
Aspect Blanking-Half
,
Aspect Blanking-Black
Parallel Remote (4/5)
Side by Side
,
Wipe
,
Butterfly
,
Blending
,
Error Notify Clear
,
Audio Level Meter
,
ALM
Hold Reset
,
Time Code
Parallel Remote (5/5)
Difference
,
Checkerboard
,
L/R Switch
,
Horopter Check
,
Flip H
For the pin assignment, see “PARALLEL REMOTE connector” in Location and Function of
Parts on page 17 (BVM-E250A) or page 20 (BVM-E170A).
Menu
Function and operation ([
]: factory setting)