Sony BVME170A User Manual (Operating Instructions - BVM-E250A / BVM-E170A) - Page 84

Enter New Password, Bottom Left

Page 84 highlights

Chapter 3 Menu On Screen Set Menu Service 708 Service 608 OSD Level Audio Level Meter Audio CH Position Transparency Peak Hold Time Code VITC/LTC Position Level Over Range Password Change Password Function and operation ([ ]: factory setting) Sets Service when Type is set to 708. You can select from Service1 to Service6. [Service1] Sets Service when Type is set to 608 (VBI) or 608 (708). You can select from CC1 to CC4 or Text1 to Text4. [CC1] Sets the luminance of the letter. You can select from High (bright), or [Low] (dark). Sets the audio level meter. When the BKM-250TG is installed, you can select the item. The setting is effective for the input signal of the BKM-250TG. Note As the audio level meter is superimposed on the video signal, the audio level meter may be cut partially because of the scan mode setting of the monitor. Sets the audio channel. You can select from [CH1-CH8] or CH9-CH16. Sets the display position of the audio level meter. You can select from [Bottom] (bottom) or Top (top). Sets the transparency of the background of the audio level meter. You can select from Black (black) or [Half] (translucence). Sets the peak hold mode of the audio level meter. [Off]: The peak hold does not function. Auto: The peak hold is automatically released after about 1 second. Manual Reset: The peak hold is released manually. To release the peak hold, select ALM Hold Reset (page 79) in the Function Switch menu of the Function Setting menu or set ALM Hold Reset to on by pressing the ALM Hold Reset button1) of the controller. 1)ALM Hold Reset is assigned to the controller in the Function Key menu (page 92) of the Controller menu. Sets the time code. The setting is effective when the SDI signal is input. Note As the time code is superimposed on the video signal, the time code may be cut partially because of the scan mode setting of the monitor. Sets the type of the time code. You can select from [VITC] or LTC. Sets the display position of the time code. You can select from Top Left (top left), [Top Center] (top center), Top Right (top right), Bottom Left (bottom left), Bottom Center (bottom center) or Bottom Right (bottom right). Sets the luminance of the time code. You can select High (bright) or [Low] (dark). When a portion of the signal exceeds the dynamic range of the internal signal processing circuit, it is determined as Over Range. This menu sets whether or not to display a zebra pattern on the detected Over Range portion ([Off], On). When Over Range is detected, adjust the contrast or brightness to a lower level. Notes • When Over Range occurs, the OVER RANGE lamp on the front of the unit lights in amber regardless of the setting of this menu. • When Gamut Error Display of the Function Setting menu is set to On, the zebra pattern in the area where the error was detected is also included as a detection target of Over Range. Sets the password for the menu. Enter a four-digit number for the password. [9999] Changes the password. Enter New Password: Enter a new password with the numeric buttons and press the ENTER (Ent) button. Re-Enter Password: Enter the new password again and press the ENTER (Ent) button. The password is registered. To change it, press the MENU button. 84 System Configuration Menu

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155

84
System Configuration Menu
Chapter 3
Menu
On Screen Set
Service 708
Sets Service when Type is set to 708.
You can select from
Service1
to
Service6
.
[Service1]
Service 608
Sets Service when Type is set to 608 (VBI) or 608 (708).
You can select from
CC1
to
CC4
or
Text1
to
Text4
.
[CC1]
OSD Level
Sets the luminance of the letter.
You can select from
High
(bright), or
[Low]
(dark).
Audio Level Meter
Sets the audio level meter.
When the BKM-250TG is installed, you can select the item.
The setting is effective for the input signal of the BKM-250TG.
Note
As the audio level meter is superimposed on the video signal, the audio level meter may be
cut partially because of the scan mode setting of the monitor.
Audio CH
Sets the audio channel.
You can select from
[CH1-CH8]
or
CH9-CH16
.
Position
Sets the display position of the audio level meter.
You can select from
[Bottom]
(bottom) or
Top
(top).
Transparency
Sets the transparency of the background of the audio level meter.
You can select from
Black
(black) or
[Half]
(translucence).
Peak Hold
Sets the peak hold mode of the audio level meter.
[Off]:
The peak hold does not function.
Auto:
The peak hold is automatically released after about 1 second.
Manual Reset:
The peak hold is released manually.
To release the peak hold, select ALM Hold Reset (page 79) in the Function Switch menu
of the Function Setting menu or set ALM Hold Reset to on by pressing the ALM Hold
Reset button
1)
of the controller.
1)ALM Hold Reset is assigned to the controller in the Function Key menu (page 92) of the Controller
menu.
Time Code
Sets the time code.
The setting is effective when the SDI signal is input.
Note
As the time code is superimposed on the video signal, the time code may be cut partially
because of the scan mode setting of the monitor.
VITC/LTC
Sets the type of the time code.
You can select from
[VITC]
or
LTC
.
Position
Sets the display position of the time code.
You can select from
Top Left
(top left),
[Top Center]
(top center),
Top Right
(top right),
Bottom Left
(bottom left),
Bottom Center
(bottom center) or
Bottom Right
(bottom right).
Level
Sets the luminance of the time code.
You can select
High
(bright) or
[Low]
(dark).
Over Range
When a portion of the signal exceeds the dynamic range of the internal signal processing
circuit, it is determined as Over Range. This menu sets whether or not to display a zebra
pattern on the detected Over Range portion (
[Off]
,
On
).
When Over Range is detected, adjust the contrast or brightness to a lower level.
Notes
When Over Range occurs, the OVER RANGE lamp on the front of the unit lights in amber
regardless of the setting of this menu.
When Gamut Error Display of the Function Setting menu is set to On, the zebra pattern in
the area where the error was detected is also included as a detection target of Over Range.
Password
Sets the password for the menu.
Enter a four-digit number for the password.
[9999]
Change Password
Changes the password.
Enter New Password:
Enter a new password with the numeric buttons and press the
ENTER (Ent) button.
Re-Enter Password:
Enter the new password again and press the ENTER (Ent) button.
The password is registered.
To change it, press the MENU button.
Menu
Function and operation ([