Pressor foot solenoid does not oper, Replace the main PCB with a new one.
View all Brother International BES-116 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 147 highlights
Chapter 10 Troubleshooting Symptom Measures Thread trimmer solenoid does not operate. • Check to see if connection from the thread trimmer solenoid to connector P20 of the main PCB is proper. • Check the resistance value of the thread trimmer solenoid which does not operate with the connector section. The normal resistance value is approximately 27Ω. If it is faulty, replace the solenoid with a new one. In this case, the main PCB may also be faulty. Also replace the main PCB with a new one if it does not operate properly even after replacing the solenoid. • Replace the main PCB with a new one. Pressor foot solenoid does not operate. • Check to see if connection from the pressor foot solenoid to connector P20 of the main PCB is proper. • Check the resistance value of the pressor foot solenoid which does not operate with the connector section. The normal resistance value is approximately 80Ω. If it is faulty, replace the solenoid with a new one. In this case, the main PCB may also be faulty. Also replace the mainPCB with a new one if it does not operate properly even after replacing the solenoid. • Replace the main PCB with a new one. BES-116AC 145