Dell PowerEdge 2900 Hardware Owner's Manual (PDF) - Page 103
x8 Plus 1x2 Drive Configuration, board. See
View all Dell PowerEdge 2900 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 103 highlights
1x8 Plus 1x2 Drive Configuration If the optional 1x2 SAS backplane is installed in the flex bay, make the following cable connections: • Connect SAS_0 on the SAS controller daughter card to connector SAS_A on the 1x8 SAS backplane board. See Figure 3-31. • Connect SAS_1 on the SAS controller daughter card to SAS_B_IN on the 1x2 SAS backplane board. See Figure 3-31. • Connect SAS_B_OUT on the 1x2 SAS backplane board to connector SAS_B on the 1x8 SAS backplane board. See Figure 3-31. Installing System Components 103
Installing System Components
103
1x8 Plus 1x2 Drive Configuration
If the optional 1x2 SAS backplane is installed in the flex bay, make the following cable connections:
•
Connect SAS_0 on the SAS controller daughter card to connector SAS_A on the 1x8 SAS
backplane board. See Figure 3-31.
•
Connect SAS_1 on the SAS controller daughter card to SAS_B_IN on the 1x2 SAS backplane
board. See Figure 3-31.
•
Connect SAS_B_OUT on the 1x2 SAS backplane board to connector SAS_B on the 1x8 SAS
backplane board. See Figure 3-31.