Table 1-6. LCD Status Messages (continued) Code Text Causes Corrective Actions E2112 Mem Spare DIMM ## The system BIOS has spared the See "Troubleshooting System memory because it has Memory" on page 124. determined that the memory had too many errors. "## & ##" represents the DIMM pair implicated by the BIOS. E2113 Mem Mirror DIMM ## & ## They system BIOS has disabled memory mirroring because it has determined that one half of the mirror has had too many errors. "## & ##" represents the DIMM pair implicated by the BIOS. See "Troubleshooting System Memory" on page 124. E2118 Fatal NB Mem CRC One of the connections in the Fully Buffered DIMM (FBD) memory subsystem link on the Northbound side has failed. See "Troubleshooting System Memory" on page 124. E2119 Fatal SB Mem CRC One of the connections in the See "Troubleshooting System FBD memory subsystem link on Memory" on page 124. the Southbound side has failed. I1910 Intrusion System cover has been removed. Information only. I1911 >3 ERRs Chk Log LCD overflow message. Check the SEL for details on the A maximum of three error events. messages can display sequentially on the LCD. The fourth message displays as the standard overflow message. I1912 SEL Full System Event Log is full of events, and is unable to log any more events. Clear the log by deleting event entries. W1228 ROMB Batt < 24hr Warns predictively that the RAID Replace RAID battery. See battery has less than 24 hours of "Replacing the SAS RAID charge left. Controller Daughter Card Battery" on page 96. NOTE: For the full name of an abbreviation or acronym used in this table, see the "Glossary" on page 169. About Your System 25