Dell PowerEdge 2900 Hardware Owner's Manual (PDF) - Page 28
Single-rank DIMM - The, Error: Incorrect memory - usb 3 0
View all Dell PowerEdge 2900 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Table 1-7. System Messages (continued) Message Causes Corrective Actions Dual-rank DIMM paired with Single-rank DIMM - The following DIMM/rank has been disabled by BIOS: DIMM x Rank y Mismatched DIMMs installed; faulty Ensure that all pairs of memory modules memory module(s). The system has are of the same type and size and that detected a dual-rank DIMM paired they are properly installed. See with a single-rank DIMM. The second "Memory" on page 82. If the problem rank of the dual-rank DIMM will be persists, see "Troubleshooting System disabled. Memory" on page 124. Diskette drive n seek failure Incorrect configuration settings in the Run the System Setup program to System Setup program. correct the settings. See "Using the System Setup Program" on page 35. Faulty or improperly installed diskette Replace the diskette. If the problem drive. persists, see "Troubleshooting a Diskette Drive" on page 126. Loose diskette drive interface cable, or Reseat diskette drive interface cable, or loose power cable. power cable. See "Troubleshooting a Diskette Drive" on page 126. Diskette read failure Faulty or improperly inserted diskette. Replace the diskette. If the problem persists, see "Troubleshooting a Diskette Drive" on page 126. Diskette subsystem reset failed Faulty or improperly installed diskette. Replace the diskette. If the problem persists, see "Troubleshooting a Diskette Drive" on page 126. Drive not ready Diskette missing from or improperly Replace the diskette. If the problem inserted in diskette drive. persists, see "Troubleshooting a Diskette Drive" on page 126. Error: Incorrect memory configuration. DIMMs must be installed in pairs of matched memory size, speed, and technology. Mismatched or unmatched DIMMs installed; faulty or improperly seated memory module(s). Ensure that all pairs of memory modules are of the same type and size and that they are properly installed. See "Memory" on page 82. If the problem persists, see "Troubleshooting System Memory" on page 124. Error: Memory failure detected. Memory size reduced. Replace the faulty DIMM as soon as possible. Faulty or improperly seated memory See "Troubleshooting System Memory" module(s). on page 124. !!*** Error: Remote Access Controller initialization failure*** RAC virtual USB devices may not be available... Remote Access Controller initialization failure Ensure that the Remote Access Controller is properly installed. See "Installing a RAC Card" on page 87. 28 About Your System