POST Mem Test, SBE Log Disable - memory configuration

Page 24 highlights

Table 1-6. LCD Status Messages (continued) Code E2017 E2018 E2019 E201A E201B E201C E201D E201E E201F E2020 E2021 E2022 E2110 E2111 Text Causes Corrective Actions Timer Fail Timer refresh failure. See "Getting Help" on page 147. Prog Timer Programmable interval timer error See "Getting Help" on page 147. Parity Error Parity error. See "Getting Help" on page 147. SIO Err SIO failure. See "Getting Help" on page 147. Kybd Controller Keyboard controller failure. See "Getting Help" on page 147. SMI Init System management interrupt See "Getting Help" on page 147. (SMI) initialization failure. Shutdown Test BIOS shutdown test failure. See "Getting Help" on page 147. POST Mem Test BIOS POST memory test failure. See "Troubleshooting System Memory" on page 124. If problem persists, see "Getting Help" on page 147. DRAC Config Dell remote access controller Check screen for specific error (DRAC) configuration failure. messages. Ensure that DRAC cables and connectors are properly seated. If problem persists, see your DRAC documentation. CPU Config CPU configuration failure. Check screen for specific error messages. Memory Population Incorrect memory configuration. Check screen for specific error Memory population order messages. See "Troubleshooting incorrect. System Memory" on page 124. POST Fail General failure after video. Check screen for specific error messages. MBE DIMM ## & ## One of the DIMMs in the set implicated by "## & ##" has had a memory multi-bit error (MBE). See "Troubleshooting System Memory" on page 124. SBE Log Disable DIMM ## The system BIOS has disabled See "Troubleshooting System memory single-bit error (SBE) Memory" on page 124. logging, and will not resume logging further SBEs until the system is rebooted. "##" represents the DIMM implicated by the BIOS. 24 About Your System

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

24
About Your System
E2017
Timer Fail
Timer refresh failure.
See "Getting Help" on page 147.
E2018
Prog Timer
Programmable interval timer
error
See "Getting Help" on page 147.
E2019
Parity Error
Parity error.
See "Getting Help" on page 147.
E201A
SIO Err
SIO failure.
See "Getting Help" on page 147.
E201B
Kybd Controller
Keyboard controller failure.
See "Getting Help" on page 147.
E201C
SMI Init
System management interrupt
(SMI) initialization failure.
See "Getting Help" on page 147.
E201D
Shutdown Test
BIOS shutdown test failure.
See "Getting Help" on page 147.
E201E
POST Mem Test
BIOS POST memory test failure.
See "Troubleshooting System
Memory" on page 124. If problem
persists, see "Getting Help" on
page 147.
E201F
DRAC Config
Dell remote access controller
(DRAC) configuration failure.
Check screen for specific error
messages.
Ensure that DRAC cables and
connectors are properly seated. If
problem persists, see your DRAC
documentation.
E2020
CPU Config
CPU configuration failure.
Check screen for specific error
messages.
E2021
Memory
Population
Incorrect memory configuration.
Memory population order
incorrect.
Check screen for specific error
messages. See "Troubleshooting
System Memory" on page 124.
E2022
POST Fail
General failure after video.
Check screen for specific error
messages.
E2110
MBE DIMM ## & ##
One of the DIMMs in the set
implicated by "## & ##" has
had a memory multi-bit error
(MBE).
See "Troubleshooting System
Memory" on page 124.
E2111
SBE Log Disable
DIMM ##
The system BIOS has disabled
memory single-bit error (SBE)
logging, and will not resume
logging further SBEs until the
system is rebooted. "##"
represents the DIMM implicated
by the BIOS.
See "Troubleshooting System
Memory" on page 124.
Table 1-6.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions