Dell PowerEdge T105 Hardware Owner's Manual (PDF) - Page 22
CAUTION! NVRAM_CLR, Table 1-6., System Messages, Message, Causes, Corrective Actions
View all Dell PowerEdge T105 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Table 1-6. System Messages (continued) Message Causes Corrective Actions Bad error-correction The diskette or hardcode (ECC) on disk read drive controller detected an uncorrectable read error. See "Troubleshooting a Diskette Drive" on page 116 or "Troubleshooting a Hard Drive" on page 120. CAUTION! NVRAM_CLR jumper is installed on system board. Please run SETUP NVRAM jumper is installed. After an NVRAM jumper is installed, run the System Setup program. See "Using the System Setup Program" on page 31. CD-ROM drive not found The operating system See "Troubleshooting an cannot read from the Optical Drive" on CD-ROM drive. page 118. Controller has failed The hard drive or the See "Troubleshooting a associated controller is Hard Drive" on page 120. defective. Data error The diskette drive or hard drive cannot read the data. For the operating system, run the appropriate utility to check the file structure of the diskette drive or hard drive. See your operating system documentation for information on running these utilities. Decreasing available memory One or more memory modules might be faulty or improperly seated. Reinstall the memory modules and, if necessary, replace them. See "Troubleshooting System Memory" on page 114. 22 About Your System