Table 1-6., System Messages, Message, Causes, Corrective Actions, See Troubleshooting - processor
View all Dell PowerEdge T105 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Table 1-6. System Messages (continued) Message Diskette drive 0 seek failure Diskette read failure Diskette subsystem reset failed Diskette write protected Drive not ready General failure Hard disk Fan was not detected Causes Corrective Actions A cable might be loose See "Troubleshooting a or the system Diskette Drive" on configuration page 116. information might not match the hardware configuration. The diskette might be defective, or a cable might be loose. If the diskette-drive indicator turns on, try a different disk. See "Troubleshooting a Diskette Drive" on page 116. The diskette drive controller might be faulty. Run the system diagnostics. See "Running the System Diagnostics" on page 128. The diskette is writeprotected. Slide the write-protect notch to the open position. No diskette is in the Insert a diskette in the drive. drive. The operating system is This message is usually unable to carry out the followed by specific command. information. Take the appropriate action to resolve the problem. The processor cooling fan is faulty or the fan assembly is not installed correctly. Ensure that the processor cooling shroud is properly installed. See "Troubleshooting System Cooling Problems" on page 113 and "Microprocessor" on page 79. About Your System 23