Epson 12000XL Users Guide - Page 65
Environmental Specifications, Interface Specifications
View all Epson 12000XL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
User's Guide Technical Specifications Power consumption Operating: ❏ Average 30 W or below (without the optional Transparency Unit) ❏ Average 40 W or below (with the optional Transparency Unit) ❏ Max. 40 W or below (without the optional Transparency Unit) ❏ Max. 50 W or below (with the optional Transparency Unit) Ready mode: ❏ Approx. 20 W (without the optional Transparency Unit) ❏ Approx. 22 W (with the optional Transparency Unit) Sleep mode: ❏ 2.8 W or below (without the optional Transparency Unit) (100 V, 115 V, 230 V) ❏ After approx 14 minutes from no operation (without ESC! Command) Power supply OFF: ❏ 0.5 W or below (ErP Lot6: "Tier2" correspondence) Environmental Specifications Temperature Humidity Operating conditions Operating Storage Operating Storage 5 to 35 °C (41 to 95 °F) -25 to 60 °C (-13 to 140 °F) 10 to 80% (without condensation) 10 to 85% (without condensation) Ordinary office or home conditions. Avoid operating the scanner in direct sunlight, near a strong light source, or in extremely dusty conditions. Interface Specifications USB Interface Interface type Electrical standard Connector type Hi-Speed USB Full Speed mode (12 Mbits per second) and Hi-Speed mode (480 Mbits per second) of Universal Serial Bus Specification Revision 2.0. One Type B port 65