Epson ActionPrinter 4000 User Manual - Page 218
Same as for Pins 19-30., in paper out state.
View all Epson ActionPrinter 4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 218 highlights
Interface Specifications printer controller is reset to its power-up state and the print buffer is cleared. This level is normally HIGH; its pulse width must be more than 50 microseconds at the receiving terminal. 32 - ERROR OUT This level becomes LOW when the printer is: 1) in paper out state. 2) off line. 3) in error state. 33 - GND 34 - NC - Same as for Pins 19-30. - Not used. 35 - - OUT Pulled up to 5V through 3.3 Kohm resistance. 36 - SLCT IN IN The DC1/DC3 code is valid only when this signal is HIGH. (Internal fixing can be carried out with Jumper J10. The level of this signal is factory-set to , LOW.) 8-10 Technical Specifications
Interface Specifications
printer controller is reset to its power-up
state and the print buffer is cleared. This
level is normally HIGH; its pulse width
must be more than 50 microseconds at
the receiving terminal.
32
-
ERROR
OUT
This level becomes LOW when the
printer is:
1) in paper out state.
2) off line.
3) in error state.
33
-
GND
-
Same as for Pins 19-30.
34
-
NC
-
Not used.
35
-
-
OUT
Pulled up to 5V through 3.3 Kohm
resistance.
36
-
SLCT
IN
IN
The DC1/DC3 code is valid only when
this signal is HIGH. (Internal fixing can
be carried out with Jumper J10. The
level of this signal is factory-set to
, LOW.)
8-10
Technical Specifications