HP DL120 ProLiant DL120 Generation 5 Server Maintenance and Service Guide - Page 67
System fans
UPC - 884962061909
View all HP DL120 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
System fans The server has three system fans located on the chassis' center wall. The figure below identifies the system fans by their device number and shows their corresponding cable connections. Device number 1 2 3 System board connector CPU_FAN1 CPU_FAN2 SYSFAN NOTE: Fan 1 and 2 are for the processor and DIMMs; fan 3 is for the expansion boards. A new system fan can be installed to allow the server to operate properly in case the default system fan becomes defective. NOTES: • If you are replacing the system fans 1 or 2, remove the air baffle first to be able to unlatch the fan cable from the chassis. Reinstall the air baffle after installing the new system fan. • If you are replacing the system fan 3, remove the PCI riser board assembly first to be able to unlatch the fan cable from the chassis. Reinstall the PCI riser board assembly after installing the new system fan. Removal and replacement procedures 67