Table 1-5 Interpreting Smart Array P700m runtime LEDs LED ID 1 2 3 4 5 6 7 8 9 10 Color Amber Amber Amber Amber Green Green Green Green Green Green Name CR10 CR9 CR1 CR2 CR3 CR4 CR5 CR6 CR7 CR8 LED name and interpretation Thermal Alert LED. This LED is not used. System Error LED. The controller ASIC has locked up and cannot process any commands. Diagnostics Error LED. One of the server diagnostics utilities has detected a controller error. Disk Failure LED. A physical disk connected to the controller has failed. See the Fault LED on each disk to determine the failed disk. Activity LED for SAS port 2. Activity LED for SAS port 1. Command Outstanding LED. Indicates that the controller is working on a command from the host driver. Controller Heartbeat LED. This LED flashes every two seconds to indicate controller health. Gas Pedal LED. This LED, with item 10 (CR8), indicates the amount of controller CPU activity. See Table 1-6. Idle Task LED. This LED, with item 9 (CR7), indicates the amount of controller CPU activity. See Table 1-6. Table 1-6 Determining the Smart Array P700m controller CPU activity level LED 9 (Gas Pedal) Status Off Flashing On Steady On steady LED 10 (Idle Task) Status Flashing Off Off On Steady Controller CPU activity level 0 to 25% 25 to 50% 50% to 75% 75% to 100% NOTE: During server power on, each runtime LED illuminates randomly until POST completes. Smart Array P700m controller features 17