HP StorageWorks 300 HP StorageWorks 300 Virtual Library System user guide (AH1 - Page 110

Table 7 CLI con, guration commands, Command, Usage

Page 110 highlights

Table 7 CLI configuration commands Command Usage 1 updateFC Changes the default FC host port connection settings. Where the options are: -a - ID number of node to modify (0, ...) (optional) -i - Fibre Channel index (0, 1, ...) (required) -l - If attached in arbitrated loop mode, specifies a hard ALPA value between 0 and 125. A value of -1 specifies a dynamically assigned ALPA. If not attached to an arbitrated loop, this parameter is ignored (required) -r - Port number of the FC port to modify (required) -s - Preferred speed(s) (0-Auto, 1-One GB, 2-Two GB, 4-Four GB, or 10-Ten GB) (required) -t - Preferred topology(s) (0-Auto, 1-Point to Point, 2-Loop, 3-Fabric, or 4-Public Loop) (required) -h - Displays command usage information (optional) setOverSubscription Enables or disables oversubscription and specifies the percent storage remaining for notification. Where the options are: -e - Enable/disable oversubscription (0-Disabled or 1-Enabled) (required) -p - Percentage of capacity remaining for alert notification (required) -h - Displays command usage information (optional) getOverSubscription Returns whether the oversubscription feature is enabled or disabled and the capacity remaining percentage for notification alert. Oversubscription is enabled when "enabled = 0". Oversubscription is disabled when "enabled = 1". getLunMap Returns existing LUN mapping configured on the VLS for the LUN specified. Where the options are: -a - Number of the node (0, ...) (required) -l - LUN number of device whose LUN map you wish to view (required) -h - Displays command usage information (optional) getLibTypes Returns a list of available library emulation types. Displays each library emulation's name, type, product, revision, and vendor information. createLibrary Creates a new library with the specified maximum number of cartridge slots, input/export ports, and tape drives. Where the options are: -a - Node ID of the node on which the library emulation will reside (0, ...) (required) -l - LUN number to assign to library (-1 to 128) (optional) -n - Maximum number of tape drives (required) -p - Product (spaces allowed) (MSL6000, ...) (required) -pm - FC port to which this library is mapped (0, 1, ...) (required) -pt - Maximum number of input/export ports (required) -r - Revision (0430, ...) (required) -sl - Maximum number of cartridge slots (required) -t - Library type name (required) -v - Vendor (HP, ...) (required) -y - Library type to emulate (2051, ...) (required) -h - Displays command usage information (optional) 110 CLI command set

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180

Table 7 CLI con
guration commands
Command
Usage
1
updateFC
Changes the default FC host port connection settings. Where
the options are:
-a
<n>
- ID number of node to modify (0, ...) (optional)
-i
<n>
- Fibre Channel index (0, 1, ...) (required)
-l
<n>
- If attached in arbitrated loop mode, speci
es a
hard ALPA value between 0 and 125. A value of -1 speci
es
a dynamically assigned ALPA. If not attached to an arbitrated
loop, this parameter is ignored (required)
-r
<n>
- Port number of the FC port to modify (required)
-s
<n>
- Preferred speed(s) (0-Auto, 1-One GB, 2-Two GB,
4-Four GB, or 10-Ten GB) (required)
-t
<n>
- Preferred topology(s) (0-Auto, 1-Point to Point, 2-Loop,
3-Fabric, or 4-Public Loop) (required)
-h
- Displays command usage information (optional)
setOverSubscription
Enables or disables oversubscription and speci
es the percent
storage remaining for noti
cation. Where the options are:
-e
<n>
- Enable/disable oversubscription (0-Disabled or
1-Enabled) (required)
-p
<n>
- Percentage of capacity remaining for alert noti
cation
(required)
-h
- Displays command usage information (optional)
getOverSubscription
Returns whether the oversubscription feature is enabled or
disabled and the capacity remaining percentage for noti
cation
alert. Oversubscription is enabled when "
enabled = 0
".
Oversubscription is disabled when "
enabled = 1
".
getLunMap
Returns existing LUN mapping con
gured on the VLS for the
LUN speci
ed. Where the options are:
-a
<n>
- Number of the node (0, ...) (required)
-l
<n>
- LUN number of device whose LUN map you wish
to view (required)
-h
- Displays command usage information (optional)
getLibTypes
Returns a list of available library emulation types. Displays
each library emulation’s name, type, product, revision, and
vendor information.
createLibrary
Creates a new library with the speci
ed maximum number of
cartridge slots, input/export ports, and tape drives. Where
the options are:
-a
<n>
- Node ID of the node on which the library emulation
will reside (0, ...) (required)
-l
<n>
- LUN number to assign to library (-1 to 128) (optional)
-n
<n>
- Maximum number of tape drives (required)
-p
<s>
- Product (spaces allowed) (MSL6000, ...) (required)
-pm
<n>
- FC port to which this library is mapped (0, 1, ...)
(required)
-pt
<n>
- Maximum number of input/export ports (required)
-r
<s>
- Revision (0430, ...) (required)
-sl
<n>
- Maximum number of cartridge slots (required)
-t
<s>
- Library type name (required)
-v
<s>
- Vendor (HP, ...) (required)
-y
<n>
- Library type to emulate (2051, ...) (required)
-h
- Displays command usage information (optional)
110