Honeywell HPF24S8 Installation Instructions - Page 19

NEC Power-limited Wiring Requirements

Page 19 highlights

NEC Power-limited Wiring Requirements Installation 2.4 NEC Power-limited Wiring Requirements Power-limited and nonpower-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25" away from any nonpower-limited circuit wiring. Furthermore, all power-limited circuit wiring and nonpower-limited circuit wiring must enter and exit the cabinet through different conduits. One such example of this is shown below. Your specific application may require different conduit knockouts to be used. Any conduit knockouts may be used. For power-limited applications, use of conduit is optional. AC Power Nonpower-limited Output Circuits Power-limited Circuits Relay Contacts Nonpower-limited Circuit Input Circuits Power-limited Circuit Specific Application Power & SLC are Power-limited Circuits *If the SLC device does not match the one in this figure, refer to the SLC manual appendix, which contains wiring conversion charts for type V and type H modules. Figure 2.6 Power-limited Wiring Example 24fspwrltpH.wmf HPF24S Series Power Supplies - P/N 52751:D3 5/11/2010 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

HPF24S Series Power Supplies —
P/N 52751:D3
5/11/2010
19
NEC Power-limited Wiring Requirements
Installation
2.4
NEC Power-limited Wiring Requirements
Power-limited and nonpower-limited circuit wiring must remain separated in the cabinet.
All
power-limited circuit wiring must remain at least 0.25” away from any nonpower-limited circuit
wiring.
Furthermore, all power-limited circuit wiring and nonpower-limited circuit wiring must
enter and exit the cabinet through different conduits.
One such example of this is shown below.
Your specific application may require different conduit knockouts to be used.
Any conduit
knockouts may be used.
For power-limited applications, use of conduit is optional.
Figure 2.6
Power-limited Wiring Example
AC Power
Nonpower-limited
Output Circuits
Power-limited Circuits
Relay Contacts
Nonpower-limited Circuit
Input Circuits
Power-limited Circuit
Specific Application
Power & SLC are
Power-limited Circuits
24fspwrltpH.wmf
*If the SLC device does
not match the one in this
figure, refer to the SLC
manual appendix, which
contains wiring conver-
sion charts for type V
and type H modules.