IBM DJSA-210 Hard Drive Specifications - Page 166
Sense Condition F0h: vendor specific, Temperature is Value/2-20°C
View all IBM DJSA-210 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 166 highlights
13.27 Sense Condition (F0h: vendor specific) Command Block Output Registers Register 7 6 5 4 3 2 1 0 Data Feature 0 0 0 0 0 0 0 1 Sector Count Sector Number Cylinder Low Cylinder High Device/Head 1 - 1 D - - - - Command 1 1 1 1 0 0 0 0 Command Block Input Registers Register 7 6 5 4 3 2 1 0 Data Error see below Sector Count V V V V V V V V Sector Number N Cylinder Low Cylinder High Device/Head - - - D - - - - Status see below Error Register 76543210 CRC UNC 0 IDN 0 ABT T0N AMN 00000V00 Status Register 7 6 5 4 3 2 10 BSY RDY DF DSC DRQ COR IDX ERR V V V - V - -V Figure 104. Sense Condition Command (F0h) The Sense Condition command is used to sense temparature in a device.This command is executable winthout spinning up even if a device is started with No Spin Up option. Output Parameters To The Device Feature The Feature register must be set to 01h. All other value are rejected with setting ABORT bit in status register. Input Parameters From The Device Sector Count The Sector Count register contains result value. Value Description 00h Temperature is equal to or lower than -20°C 01h-FEh Temperature is (Value/2-20)°C FFh Temperature is higher than 107°C N Not recommendable condition for start up. If over stressed condition is detected, this bit will be set to one. Travelstar 32GH/30GT/20GN hard disk drive specifications 152