IC Realtime IPFX-D80V-IRW1 Product Manual - Page 119

Record Linkage

Page 119 highlights

Period Step 2 Set arming periods. The time period in green on the timeline is armed.  Method one: Directly press and drag the left mouse button on the timeline.  Method two: Enter an actual time period. 1) Click Setting for a day. 2) Select a time period to be enabled. 3) Enter start time and end time of a time period.  Select All or the check box of any day to synchronously set the time period of multiple days.  You can set 6 time periods per day. Step 3 Click Save. 5.1.1.2 Record Linkage The system can link record channel when an alarm event occurs. After alarm, the system stops recording after an extended time period according to the Record Delay setting. To use the record linkage function, set recording plan for motion detection alarm and enable auto recording in record control. 5.1.1.2.1 Setting Record Plan The record channel starts alarm linkage record only after the corresponding alarm type (Normal, Motion, Alarm) is enabled. Step 1 Select Setting > Storage > Schedule > Record. The Record interface is displayed. See Figure 5-3. Event 111

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193

Event
111
Period
Step 2
Set arming periods. The time period in green on the timeline is armed.
Method one: Directly press and drag the left mouse button on the timeline.
Method two: Enter an actual time period.
1)
Click
Setting
for a day.
2)
Select a time period to be enabled.
3)
Enter start time and end time of a time period.
Select
All
or the check box of any day to synchronously set the time period of
multiple days.
You can set 6 time periods per day.
Step 3
Click
Save
.
5.1.1.2
Record Linkage
The system can link record channel when an alarm event occurs. After alarm, the system stops
recording after an extended time period according to the
Record Delay
setting.
To use the record linkage function, set recording plan for motion detection alarm and enable
auto recording in record control.
5.1.1.2.1
Setting Record Plan
The record channel starts alarm linkage record only after the corresponding alarm type
(
Normal
,
Motion
,
Alarm
) is enabled.
Step 1
Select
Setting > Storage > Schedule > Record
.
The
Record
interface is displayed. See Figure 5
-
3.