Page 128 highlights
Alarm Track To enable track linkage, select Enable. Manual positioning and manual track are enabled after Alarm Track is enabled. Auto Track is enabled after Alarm Track and Auto Track are enabled. Set parameters. See Table 5-3. Table 5-3 Description of alarm track parameters Parameter Description Select Enable, the dome would automatically links to a corresponding Auto Track position and tracks an object when the intelligent rules for panoramic camera triggers an alarm. Set time for alarm track. Before an object disappears: The dome would automatically links to a Track Time corresponding position and tracks an object until the object moves out of the monitoring range when the intelligent rules for panoramic camera triggers an alarm. Custom: Set time for auto alarm track of dome. Idle Time It is an interval from the end of alarm track of dome to the start of idle mode. Set Idle Time and Idle Position. If no event needs to be tracked after passing the set idle time, the device automatically rotates to the set idle position. For example, set the Idle Time to be five seconds and the Idle Idle Position Position to be the preset point 1. When the dome does not start tracking after five seconds, it automatically rotates to the preset point 1. To set Idle Position, first set a preset point. For preset point, see "4.3.2.1 Preset." Click Save. Event 120