Icom IC-7610 Instruction Manual advanced - Page 16

Delta TX function, Delta TX monitor function - noise reduction

Page 16 highlights

2. ADVANCED OPERATIONS ∂TX function The ∂TX function shifts the transmit frequency up to ±9.99 kHz without shifting the receive frequency. 1. Push TX . ••The ∂TX function turns ON. LPushing TX turns the ∂TX function ON or OFF. LWhile using the Fine Tuning function (See Basic manual section 3), the ∂TX frequency is displayed in 4 digits, instead of 3. ∂TX frequency 2. Rotate RIT/ TX to set the ∂TX frequency to match the receiving station's frequency. Set the ∂TX frequency. DD∂TX monitor function When the ∂TX function is ON, you can directly monitor the operating frequency by holding down XFC . While holding down XFC . LW hile monitoring, the TX/RX indicator lights green and the Noise Reduction, Notch Filter and Twin PBT settings are cleared. LTo reset the ∂TX frequency to "0.00," hold down CLEAR for 1 second. LYou can add the frequency shift to the operating frequency by holding down TX for 1 second. 3. To turn OFF the ∂TX function, push TX . 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

12
2. ADVANCED OPERATIONS
TX function
The
TX function shifts the transmit frequency up to
±9.99 kHz without shifting the receive frequency.
1. Push
TX
.
• The
TX function turns ON.
L
Pushing
TX
turns the
TX function ON or OFF.
L
While using the Fine Tuning function (See Basic
manual section 3), the
TX frequency is displayed in
4 digits, instead of 3.
2. Rotate
RIT/
TX
to set the
TX frequency to
match the receiving station’s frequency.
L
To reset the
TX frequency to “0.00,” hold down
CLEAR
for 1 second.
L
You can add the frequency shift to the operating
frequency by holding down
TX
for 1 second
.
3. To turn OFF the
TX function, push
TX
.
TX frequency
Set the ∂
TX frequency.
While holding down
XFC
.
D
TX monitor function
When the
TX function is ON, you can directly monitor
the operating frequency by holding down
XFC
.
L
While monitoring, the TX/RX indicator lights green
and the Noise Reduction, Notch Filter and Twin PBT
settings are cleared.