Icom IC-7610 Instruction Manual advanced - Page 90

REF adjustment, Calibration Marker

Page 90 highlights

11. OTHER FUNCTIONS REF adjustment You can perform a rough frequency calibration by receiving the radio station WWV, WWVH, or other frequency signals. NOTE: ••The transceiver has been adjusted and tested at the factory before being shipped out. You should not have to recalibrate. ••Before performing a frequency calibration, you have to set "Calibration Marker" to ON. ••Spurious signal waveforms may be displayed while the Calibration Marker is ON. LBefore performing a frequency calibration, set the following items as described in the table below. Operating mode USB AF RF/SQL Decent audibility AF RF/SQL Maximum RF gain TWIN PBT CLR Reset by holding down for 1 second. RIT , TX OFF (No icon) 1. Set the frequency to the standard frequency station minus 1 kHz. LIf receiving WWV or WWVH (at 15.00000 MHz) as your standard frequency, set the operating frequency to 14.99900 MHz. 2. Set "Calibration Marker" to ON. MENU » SET > Function > Calibration Marker 3. Select the "REF Adjust" item. MENU » SET > Function > REF Adjust 4. Rotate MULTI to adjust for a zero beat with the received standard signal. L"Zero beat" means that the exact same frequencies are set to 2 signals, resulting in a single tone being transmitted. 5. Set "Calibration Marker" to OFF. 6. Push EXIT several times until the MENU screen is closed. 84

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

84
11. OTHER FUNCTIONS
REF adjustment
You can perform a rough frequency calibration by
receiving the radio station WWV, WWVH, or other
frequency signals.
NOTE:
• The transceiver has been adjusted and tested at
the factory before being shipped out. You should
not have to recalibrate.
• Before performing a frequency calibration, you
have to set “Calibration Marker” to ON.
• Spurious signal waveforms may be displayed while
the Calibration Marker is ON.
L
Before performing a frequency calibration, set the
following items as described in the table below.
Operating mode
USB
AF
RF/SQL
Decent audibility
AF
RF/SQL
Maximum RF gain
TWIN PBT
CLR
Reset by holding down for 1 second.
RIT
,
TX
OFF (No icon)
1.
Set the frequency to the standard frequency
station minus 1 kHz.
L
If receiving WWV or WWVH (at 15.00000 MHz) as
your standard frequency, set the operating frequency
to 14.99900 MHz.
2.
Set “Calibration Marker” to ON.
MENU
»
SET > Function >
Calibration Marker
3.
Select the “REF Adjust” item.
MENU
»
SET > Function >
REF Adjust
4. Rotate
MULTI
to adjust for a zero beat with the
received standard signal.
L
“Zero beat” means that the exact same frequencies
are set to 2 signals, resulting in a single tone being
transmitted.
5.
Set “Calibration Marker” to OFF.
6. Push
EXIT
several times until the MENU screen
is closed.