Icom IC-7610 Instruction Manual advanced - Page 90
REF adjustment, Calibration Marker
View all Icom IC-7610 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
11. OTHER FUNCTIONS REF adjustment You can perform a rough frequency calibration by receiving the radio station WWV, WWVH, or other frequency signals. NOTE: ••The transceiver has been adjusted and tested at the factory before being shipped out. You should not have to recalibrate. ••Before performing a frequency calibration, you have to set "Calibration Marker" to ON. ••Spurious signal waveforms may be displayed while the Calibration Marker is ON. LBefore performing a frequency calibration, set the following items as described in the table below. Operating mode USB AF RF/SQL Decent audibility AF RF/SQL Maximum RF gain TWIN PBT CLR Reset by holding down for 1 second. RIT , TX OFF (No icon) 1. Set the frequency to the standard frequency station minus 1 kHz. LIf receiving WWV or WWVH (at 15.00000 MHz) as your standard frequency, set the operating frequency to 14.99900 MHz. 2. Set "Calibration Marker" to ON. MENU » SET > Function > Calibration Marker 3. Select the "REF Adjust" item. MENU » SET > Function > REF Adjust 4. Rotate MULTI to adjust for a zero beat with the received standard signal. L"Zero beat" means that the exact same frequencies are set to 2 signals, resulting in a single tone being transmitted. 5. Set "Calibration Marker" to OFF. 6. Push EXIT several times until the MENU screen is closed. 84