Icom IC-7610 Instruction Manual advanced - Page 85

About the RF/SQL Control, RF/SQL Control, When using as an RF gain/squelch control

Page 85 highlights

11. OTHER FUNCTIONS About the RF/SQL Control MENU » SET > Function > RF/SQL Control You can set the AF RF/SQL (outer) control type in the RF/SQL Control item in the set mode. ••Auto: While in the AM or FM mode, used only as a squelch control. While in the SSB, CW, RTTY, or PSK mode, used only as an RF gain control. ••SQL: Used as only a squelch control. LRF gain is fixed at maximum sensitivity. ••RF+SQL: Used as an RF gain control, and a noise squelch or S-meter squelch. When using as an RF gain/squelch control Squelch is open RF gain adjustable range is displayed (RFG) Minimum RF gain Noise squelch (FM mode) S-meter squelch adjustable range Maximum RF gain Maximum S-meter squelch When using as an RF gain control (Squelch is fixed open: SSB, CW, RTTY, PSK only) Maximum RF gain RF gain adjustable range is displayed (RFG) Minimum RF gain Maximum RF gain range When using as a squelch control (RF gain is fixed at maximum.) Noise squelch threshold Squelch is open Noise squelch (FM mode) S-meter squelch threshold S-meter squelch adjustable range Maximum S-meter squelch 79

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

79
11. OTHER FUNCTIONS
About the RF/SQL Control
MENU
»
SET > Function >
RF/SQL Control
You can set the
AF
RF/SQL
(outer) control type in the
RF/SQL Control item in the set mode.
• Auto:
While in the AM or FM mode, used only
as a squelch control.
While in the SSB, CW, RTTY, or PSK
mode, used only as an RF gain control.
• SQL:
Used as only a squelch control.
L
RF gain is fixed at maximum sensitivity.
• RF+SQL:
Used as an RF gain control, and a noise
squelch or S-meter squelch.
Noise squelch (FM mode)
S-meter squelch
threshold
S-meter squelch
adjustable range
Maximum
S-meter squelch
Squelch is open
Noise squelch
threshold
When using as an RF gain/squelch control
When using as an RF gain control
(Squelch is fixed open: SSB, CW, RTTY, PSK only)
When using as a squelch control
(RF gain is fixed at maximum.)
Noise squelch (FM mode)
S-meter squelch
adjustable range
Maximum RF gain
Maximum S-meter squelch
Minimum RF gain
RF gain
adjustable range
Squelch is open
is displayed
(RFG)
Maximum
RF gain range
Minimum
RF gain
RF gain
adjustable range
is displayed
Maximum RF gain
(RFG)