Icom IC-7610 Instruction Manual advanced - Page 45
SCOPE SET screen, SCOPE, Scope during Tx CENTER TYPE, Max Hold, CENTER Type Display
View all Icom IC-7610 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
3. ADVANCED SCOPE OPERATION SCOPE SET screen This Set screen is used to set the waveform color, Scope range for the Fixed mode, and so on. 1. Display the SPECTRUM SCOPE screen. MENU » SCOPE 2. Touch [EXPD/SET] for 1 second. 3. Rotate MAIN DIAL to scroll through the items, and then touch the item you want to set. (Example: Max Hold) 4. Touch an option to set. LSee the column to the right for details on the items. 5. To exit the SCOPE SET screen, push EXIT . TIP: How to reset to the default setting Touching the item or its option for 1 second displays the Quick menu, and then touch "Default" to reset the item/option to its default setting. Scope during Tx (CENTER TYPE) (Default: ON) Set the TX signal display to ON or OFF. Max Hold (Default: 10s Hold) Select the peak level holding function. • OFF: Turns OFF the peak level holding function. • 10s Hold: Holds the peak spectrum for 10 seconds. • ON: Continuously holds the peak spectrum. CENTER Type Display (Default: Filter Center) Select the center frequency of the SPECTRUM SCOPE screen. (Only in the Center mode) • Filter Center: D isplays the selected filter's center frequency in the center of the SPECTRUM SCOPE screen. • Carrier Point Center: Displays the carrier point frequency of the selected operating mode in the center of the SPECTRUM SCOPE screen. • Carrier Point Center (Abs. Freq.): In addition to the carrier point center setting above, the actual frequency is displayed at the bottom of the scope. L Abs. Freq. : Absolute Frequency Marker Position (Fix Type) (Default: Carrier Point) Select the marker position on the SPECTRUM SCOPE screen. (Only in the Fixed mode) • Filter Center: D isplays the Marker on the selected filter's center frequency. • Carrier Point: D isplays the Marker on the carrier point frequency of the selected operating mode. Averaging (Default: OFF) Set the FFT scope waveform averaging function to between 2 and 4, or OFF. • OFF: The FFT scope screen refreshes on each sweep time. This setting displays the critical spectrum view. • 2, 3, 4: The FFT scope screen averages 2 to 4 sweeps to smoothly display the spectrum. Waveform Type (Default: Fill) Select the outline waveform display for the FFT scope screen. • Fill: The waveform is drawn only in color. • Fill+Line: T he waveform is drawn in color with an outline. 39