Lexmark J110 Service Manual - Page 128
Diagnostics (Mode 2) - Supplies Tests, K=+ C=+ M=+ Y
View all Lexmark J110 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 128 highlights
4085-001 Diagnostics (Mode 2) - Supplies Tests For each of the following four tests, the sequence of events is the same: 1. The printheads are uncapped when the test is invoked. 2. The printheads moves to the middle of the frame to give the servicer access to the printheads and tanks under test. The data corresponding to the test being run begins updating real time on the panel as described. 3. When the test is ended by pressing Return or Stop, the carrier is homed and the printheads are capped. Ink Tank Memories This test determines the status of the electrical connection to the ink tank memories. The status is indicated real time by either "+" (good) or "-" (bad). The following screen is displayed: Ink Tank Mem Test K=+ C=+ M=+ Y=+ To exit the test, select Return or Stop. Printhead Memories This test determines the status of the electrical connection to the printhead memories. The status is indicated real time by either "+" (good) or "-" (bad). The following screen is displayed: Printhead Mem Test K=+ CMY=+ To exit the test, select Return or Stop. 3-34 Service Manual