Oki X400 X400 Programming Command Manual - Page 116
EAN-8
View all Oki X400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
EAN-8 Command Structure B4bbccc (data) D4bbccc (data) bb = ccc = (data) = Width of narrow element in dots (01~12) Bar height in dots (001~999) Bar code data (numeric); must be exactly 8 digits. Character Set Density Table 0-9 (numeric only) Value of "bb" Narrow Bar Width Magnification (mils) Factor 02 10.0 75% 03 15.0 112% 04 20.0 150% Example H100V100BD4031001234567 Notes 1. D4 provides guide bars that extend longer than the reset of the bar code. and the human readable text below the symbol. 2. The check digit is automatically calculated for EAN-8. 114
EAN-8
Command Structure
<ESC>B4bbccc (data)
<ESC>D4bbccc (data)
bb
=
Width of narrow element in dots (01~12)
ccc
=
Bar height in dots (001~999)
(data) =
Bar code data (numeric); must be exactly 8 digits.
Character Set
0-9 (numeric only)
Density Table
Value of “bb”
Narrow Bar Width
(mils)
Magnification
Factor
02
10.0
75%
03
15.0
112%
04
20.0
150%
Example
<ESC>H100<ESC>V100<ESC>BD4031001234567
Notes
1.
D4 provides guide bars that extend longer than the reset of the bar code.
and the human readable text below the symbol.
2.
The check digit is automatically calculated for EAN-8.
114