Rotate, Fixed Base Reference Point Command Structure %a a =0 1 2 3 Sets print to normal direction. Sets print to 90o CCW. Sets print to 180o CCW (upside down). Sets print to 270o CCW. Example: %3 Placement: Preceding any printed data to be rotated. Default: %0 Command Function To rotate the print direction in 90o increments without changing the location of the base reference point. The diagram below illustrates the use of the % Rotate command. Note that the entire print area is shown, but your label will probably not be as large as the entire area. Input to Printer A %0L0202H140V100MNORMAL DIRECTION %1H100V300MONE %2H200V360MTWO %3H200V410MTHREE Q1Z Printer Output 65
Rotate, Fixed Base Reference Point
Command Structure
<ESC>%a
a
=
0
Sets print to normal direction.
1
Sets print to 90
o
CCW.
2
Sets print to 180
o
CCW (upside down).
3
Sets print to 270
o
CCW.
Example:
<ESC>%3
Placement: Preceding any printed data to be rotated.
Default:
<ESC>%0
Command Function
To rotate the print direction in 90
o
increments without changing the loca-
tion of the base reference point. The diagram below illustrates the use of the
<ESC>% Rotate command. Note that the entire print area is shown, but your
label will probably not be as large as the entire area.
Input to Printer
<ESC>A
<ESC>%0<ESC>L0202<ESC>H140<ESC>V100<ESC>MNORMAL DIRECTION
<ESC>%1<ESC>H100<ESC>V300<ESC>MONE
<ESC>%2<ESC>H200<ESC>V360<ESC>MTWO
<ESC>%3<ESC>H200<ESC>V410<ESC>MTHREE
<ESC>Q1<ESC>Z
Printer Output
65