Oki X400 X400 Programming Command Manual - Page 49
Graphics, PCX
![]() |
View all Oki X400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
Graphics, PCX Command Structure GPaaaaa,(data) aaaaa = Number of bytes to be downloaded. Example: GP32000,...data... See Appendix C for a detailed example. Placement: Anywhere within the job data stream. Default: None Command Function To allow the creation and printing of graphic images using a PCX file format. Input to Printer See Appendix C for a detailed example. A H100V150GP03800,(...data...) Q1Z Printer Output Special Notes 1. The maximum number of bytes that can be downloaded is 32K (compressed). The number specified by this command includes the PCX header information. The maximum size of the uncompressed PCX file is 64K. If the uncompressed file exceeds 64K, the graphic will not print. 2. Only black and white PCX files can be downloaded. 3. The image created by this command cannot not be rotated. 4. The file size specified by this command is the DOS file size in bytes. 47