Oki X400 X400 Programming Command Manual - Page 90

Calibrate Sensor

Page 90 highlights

Calibrate Sensor Command Structure CA Example: CA Placement: This command should be sent after the sensor type has been selected with the CI command. It should not be included with print job commands. Default: There is no default for this command. Command Function To adjust the label sensor for unique media and ribbon combinations. Input to Printer Printer Output A CI2 CA Z There is no printer output for of this command. It will cause the printer to feed about 6 inches while the characteristics of the label backing or eyemark are measured. Special Notes 1. The sensor is calibrated for the currently selected sensor type (Eye-Mark or transmissive). 2. The sensor must be recalibrated whenever the sensor type is changed or incorrect label detection occurs. 3 When calibrating the sensor for the OKIPOS X400 Thermal Transfer unit operating in the thermal transfer mode, the ribbon must be installed in the printer. 88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137

Calibrate Sensor
Command Structure
<ESC>CA
Example:
<ESC>CA
Placement: This command should be sent after the sensor type has been
selected with the <ESC>CI command. It should not be included
with print job commands.
Default:
There is no default for this command.
Command Function
To adjust the label sensor for unique media and ribbon combinations.
Input to Printer
<ESC>A
<ESC>CI2
<ESC>CA
<ESC>Z
Printer Output
There is no printer output for of this command. It will cause the printer to
feed about 6 inches while the characteristics of the label backing or eye-
mark are measured.
Special Notes
1.
The sensor is calibrated for the currently selected sensor type (Eye-Mark or
transmissive).
2.
The sensor must be recalibrated whenever the sensor type is changed or in-
correct label detection occurs.
3
When calibrating the sensor for the OKIPOS X400 Thermal Transfer unit operating in
the thermal transfer mode, the ribbon must be installed in the printer.
88