Oki X400 X400 Programming Command Manual - Page 90
Calibrate Sensor
View all Oki X400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
Calibrate Sensor Command Structure CA Example: CA Placement: This command should be sent after the sensor type has been selected with the CI command. It should not be included with print job commands. Default: There is no default for this command. Command Function To adjust the label sensor for unique media and ribbon combinations. Input to Printer Printer Output A CI2 CA Z There is no printer output for of this command. It will cause the printer to feed about 6 inches while the characteristics of the label backing or eyemark are measured. Special Notes 1. The sensor is calibrated for the currently selected sensor type (Eye-Mark or transmissive). 2. The sensor must be recalibrated whenever the sensor type is changed or incorrect label detection occurs. 3 When calibrating the sensor for the OKIPOS X400 Thermal Transfer unit operating in the thermal transfer mode, the ribbon must be installed in the printer. 88