Set Sensor Type Command Structure CIa a =0 1 2 Disables Sensor. Reflective (Eye-Mark) Sensing. Transmissive (Label Gap or Notch) Sensing. Example: CI0 Placement: This command should be sent in a separate data stream. Default: CI2 (Transmissive Sensing) Command Function To select the top-of-label sensing method. Input to Printer A CI2 Z Printer Output There is no printer output as a result of this command. Special Note The reflective Eye-Mark, label gap or notch must be a minimum of 2 mm wide and extend 10 mm from the left (facing the printer) edge of the label backing. 96
Set Sensor Type
Command Structure
<ESC>CIa
a
=
0
Disables Sensor.
1
Reflective (Eye-Mark) Sensing.
2
Transmissive (Label Gap or Notch) Sensing.
Example:
<ESC>CI0
Placement: This command should be sent in a separate data stream.
Default:
<ESC>CI2 (Transmissive Sensing)
Command Function
To select the top-of-label sensing method.
Input to Printer
<ESC>A
<ESC>CI2
<ESC>Z
Printer Output
There is no printer output as a result of this command.
Special Note
The reflective Eye-Mark, label gap or notch must be a minimum of 2 mm wide and
extend 10 mm from the left (facing the printer) edge of the label backing.