Cutter Command Command Structure CKa a = Cutter control 0 Disables cutter. 1 Enables cutter. Example: CK1 Placement: Following the Q Print Quality command. Default: Cutter is disabled Command Function To control the cutting of labels when using a OKI cutter unit with the printer. Input to Printer A H20V20WB1TEST LABEL Q3 CK1 Z Special Notes 1. You must have the optional printer Cutter installed to use this function. Contact your Oki Data representative for more information. 2. Sending a Cutter Enable command to a printer without a cutter installed will cause a cut error. 34
![](/manual_guide/products/oki-data-x400-x400-programming-command-manual-82e8f1d/36.png)
Cutter Command
Command Structure
<ESC>CKa
a
=
Cutter control
0
Disables cutter.
1
Enables cutter.
Example:
<ESC>CK1
Placement: Following the <ESC>Q Print Quality command.
Default:
Cutter is disabled
Command Function
To control the cutting of labels when using a OKI cutter unit with the printer.
Input to Printer
<ESC>A
<ESC>H20<ESC>V20<ESC>WB1TEST LABEL
<ESC>Q3
<ESC>CK1
<ESC>Z
Special Notes
1.
You must have the optional printer Cutter installed to use this function. Contact
your Oki Data representative for more information.
2.
Sending a Cutter Enable command to a printer without a cutter installed will
cause a cut error.
34