Page 103 highlights

[PROJECTOR SETUP] menu 10) Press ▲▼ to select [CALIBRATION TIME]. 11) Press the button. 12) Enter the time and press the button zzMeasure brightness at a specified time. Dynamic iris is fixed to open during measurement. 13) Press ▲▼ to select [CALIBRATION MESSAGE]. 14) Press ◀▶ to switch [CALIBRATION MESSAGE]. zzThe setting will change as follows each time you press the button. [ON] [OFF] [ON] [OFF] Displays a message during calibration. Does not display a message during calibration. 15) Press ▲▼ to select [APPLY]. 16) Press the button. zzThe set [MODE] and [LINK] are enabled, and LAMP RELAY screen alert is displayed when the [LAMP RELAY] setting is [OFF]. When [CALIBRATION MESSAGE] is set to [ON], a calibration running message is displayed which will automatically disappear 30 seconds after calibration completes. zzIf the [MODE] in [BRIGHTNESS CONTROL SETUP] is not [OFF] when the button is pressed, the lamp brightness at that time is recorded as the standard brightness. zzIf the button is pressed when [LINK] is [GROUP A] to [GROUP D], the group name is displayed on the projector screen set as the same group. /,1. *5283$ brightness at the time of [APPLY]. Lamp brightness cannot be measured during the eight minutes after it is turned on because it is not steady. zzWhen [LAMP SELECT] is 2 lit or higher and the [MODE] in [BRIGHTNESS CONTROL SETUP] is operating in [AUTO] and a light fails to turn on or LAMP RELAY is performed, brightness is corrected one minute later whenever possible. zzWhen operating with [MODE] in [BRIGHTNESS CONTROL SETUP] set to [AUTO], and [LINK] is [OFF], brightness correction is performed until correction exceeds the maximum correction amount. zzIn certain projector environments, dust may accumulate on the lens or screen or inside the projector and increase variation in brightness. zzAdjust luminance control again when lamp degradation causes increased variation in brightness or a lamp is replaced. zzFor continued use longer than 24 hours, set the [BRIGHTNESS CONTROL SETUP] to [CALIBRATION TIME], or set [LAMP RELAY] ( page 101). Correction is not automatically executed when not set. zzLuminance control and iris operate simultaneously, but the iris does not operate when fully open while a brightness measurement is performed. zzThe setting of [CALIBRATION TIME] applies at the time when the time is entered. zzThe setting of [CALIBRATION MESSAGE] applies at the time when the item is switched with ◀▶ . Note zzWhen setting the [MODE] in [BRIGHTNESS CONTROL SETUP] to [AUTO] or [PC], [APPLY] luminance control after the shutter is open for at least two minutes. zzIf the shutter is closed within approx. 10 minutes from the time that the lamp turns on when operating with the [MODE] in [BRIGHTNESS CONTROL SETUP] set to [AUTO] or [PC], brightness may be corrected approx. two minutes after the shutter opens because brightness could not be measured. zzWhen operating with the [MODE] in [BRIGHTNESS CONTROL SETUP] set to [AUTO] or [PC], lamp brightness is automatically measured eight minutes after a lamp is turned on, and corrected to the same value as the screen brightness and the standard Settings ENGLISH - 103

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179

[PROJECTOR SETUP] menu
ENGLISH - 103
Settings
10)
Press
▲▼
to select [CALIBRATION
TIME].
11)
Press the <ENTER> button.
12)
Enter the time and press the <ENTER>
button
z
Measure brightness at a specified time.
Dynamic iris is fixed to open during
measurement.
13)
Press
▲▼
to select [CALIBRATION
MESSAGE].
14)
Press
◀±
to switch [CALIBRATION
MESSAGE].
z
The setting will change as follows each time
you press the button.
[ON]
[OFF]
[ON]
Displays a message during
calibration.
[OFF]
Does not display a message during
calibration.
15)
Press
▲▼
to select [APPLY].
16)
Press the <ENTER> button.
z
The set [MODE] and [LINK] are enabled, and
LAMP RELAY screen alert is displayed when
the [LAMP RELAY] setting is [OFF]. When
[CALIBRATION MESSAGE] is set to [ON], a
calibration running message is displayed which
will automatically disappear 30 seconds after
calibration completes.
z
If the [MODE] in [BRIGHTNESS CONTROL
SETUP]
is not [OFF] when the <ENTER>
button is pressed, the lamp brightness at that
time is recorded as the standard brightness.
z
If the <ENTER> button is pressed when [LINK]
is [GROUP A] to [GROUP D], the group name
is displayed on the projector screen set as the
same group.
NKPM
ITQWR C
Note
z
When setting the [MODE] in [BRIGHTNESS
CONTROL SETUP] to [AUTO] or [PC], [APPLY]
luminance control after the shutter is open for at
least two minutes.
z
If the shutter is closed within approx. 10 minutes
from the time that the lamp turns on when operating
with the [MODE] in [BRIGHTNESS CONTROL
SETUP] set to [AUTO] or [PC], brightness may be
corrected approx. two minutes after the shutter
opens because brightness could not be measured.
z
When operating with the [MODE] in [BRIGHTNESS
CONTROL SETUP] set to [AUTO] or [PC], lamp
brightness is automatically measured eight minutes
after a lamp is turned on, and corrected to the same
value as the screen brightness and the standard
brightness at the time of [APPLY]. Lamp brightness
cannot be measured during the eight minutes after
it is turned on because it is not steady.
z
When [LAMP SELECT] is 2 lit or higher and the
[MODE] in [BRIGHTNESS CONTROL SETUP] is
operating in [AUTO] and a light fails to turn on or
LAMP RELAY is performed, brightness is corrected
one minute later whenever possible.
z
When operating with [MODE] in [BRIGHTNESS
CONTROL SETUP] set to [AUTO], and [LINK] is
[OFF], brightness correction is performed until
correction exceeds the maximum correction
amount.
z
In certain projector environments, dust may
accumulate on the lens or screen or inside the
projector and increase variation in brightness.
z
Adjust luminance control again when lamp
degradation causes increased variation in
brightness or a lamp is replaced.
z
For continued use longer than 24 hours, set
the [BRIGHTNESS CONTROL SETUP] to
[CALIBRATION TIME], or set [LAMP RELAY]
(
page 101). Correction is not automatically
executed when not set.
z
Luminance control and iris operate simultaneously,
but the iris does not operate when fully open while
a brightness measurement is performed.
z
The setting of [CALIBRATION TIME] applies at the
time when the time is entered.
z
The setting of [CALIBRATION MESSAGE] applies
at the time when the item is switched with
◀±
.