Panasonic PT-DZ21KU Operating Instructions - Page 135
ENGLISH - 135, E-mail set up]
View all Panasonic PT-DZ21KU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 135 highlights
[NETWORK] menu ■■[E-mail set up] page E-mail address set in advance for use when there is a problem or when the usage time of a lamp reaches a set value. E-mail can be sent to (maximum two locations). Click [Detailed set up] → [E-mail set up]. (1) [ENABLE] Select [Enable] to use the E-mail function. (2) [SMTP SERVER NAME] (1) Enter the IP address or the server name of the E-mail server (SMTP). To enter the server name, the DNS (2) server settings are required. (3) [MAIL FROM] (3) Enter the E-mail address of the projector. (Up to 63 characters in single byte) (4) (4) [MEMO] (5) You can enter information such as the location of the projector that notifies the sender of the E-mail. (Up to (6) 63 characters in single byte) (5) [MINIMUM TIME] Change the minimum interval for the temperature warning mail. The default value is 60 minutes. In this case, another E-mail will not be sent for 60 minutes after sending the temperature warning mail even if it reaches the warning temperature. (6) [INTAKE AIR TEMPERATURE] Change the temperature setting for the temperature warning mail. A temperature warning mail is sent when the temperature exceeds this value. (7) [E-MAIL ADDRESS 1] Enter the E-mail address to be sent. (8) Settings of the conditions to send E-mail Select the conditions to send E-mail. [MAIL CONTENTS]: (7) Select either [NORMAL] or [SIMPLE]. [ERROR]: An E-mail message is sent when an error occurred in the self-diagnosis. (8) [LAMP1 RUNTIME]: An E-mail message is sent when the remaining lamp on time for the lamp 1 has reached the value set at the right field. [LAMP2 RUNTIME]: An E-mail message is sent when the remaining lamp on time for the lamp 2 has reached the value set at the right field. [LAMP3 RUNTIME]: An E-mail message is sent when the remaining lamp on time for the lamp 3 has reached the value set at the right field. [LAMP4 RUNTIME]: An E-mail message is sent when the remaining lamp on time for the lamp 4 has reached the value set at the right field. [INTAKE AIR TEMPERATURE]: An E-mail message is sent when the air intake temperature has reached the value set at the above field. [PERIODIC REPORT]: Place a check mark on this when E-mail is to be sent periodically. It will be sent on the days and time with the check mark. Note zzSet each item of [LAMP1 RUNTIME] to [LAMP4 RUNTIME] to 500 hours or less when using the optional accessory replacement lamp unit (for portrait mode) (Model No.: ET-LAD510P (1 pc), ET-LAD510PF (4 pcs)). Settings ENGLISH - 135