HP Cisco MDS 9120 Cisco MDS 9000 Family System Messages Reference (OL-15956-01 - Page 363
svctask rmsshkey
View all HP Cisco MDS 9120 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 363 highlights
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family Send documentation comments to [email protected] Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_ERR_CFG_SSH_KEY_REMOVED ) Attempt to delete SSH key (no effect) [chars]. Explanation The svctask rmsshkey command has been invoked. This command has no effect in SAN Volume Controller for Cisco MDS 9000, but is retained for compatibility. Recommended Action No action is required. Introduced Cisco MDS SAN-OS Release 1.3(1). Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_CR_START ) Cluster recovery required [chars]. Explanation The node has detected that cluster recovery is required and is waiting for human intervention to continue. Recommended Action Contact your customer support representative for assistance. Introduced Cisco MDS SAN-OS Release 1.3(1). Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_DATA_CORRUPT ) Node data corrupted - node rejected from cluster [chars]. Explanation Node data is readable but corrupted. The node has been rejected from the cluster. Recommended Action 1. Reinstall the code on the node. The node will have to be removed and added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat Step 1 with the latest level of code. 3. If the error continues, ask your customer service representative for assistance. It may be necessary to replace the Caching Services Module. Introduced Cisco MDS SAN-OS Release 1.3(1). Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_DATA_UNREADABLE ) Node data unreadable - node rejected from cluster [chars]. Explanation Node data could not be read. The node has been rejected from the cluster. Recommended Action 1. Reinstall the code on the node. The node will have to be removed and added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat Step 1 with the latest level of code. 3. If the error continues, ask your customer support representative for assistance. It may be necessary to replace the Caching Services Module. Introduced Cisco MDS SAN-OS Release 1.3(1). Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_HDW_CONFIG ) Processor not valid [chars]. Explanation The node has detected unexpected differences in the processor vital data. Recommended Action Reload the node. If the problem persists, replace the Caching Services Module. Introduced Cisco MDS SAN-OS Release 1.3(1). OL-15956-01 Cisco MDS 9000 Family System Messages Reference 2-327