HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 17
signal count, CRC errors
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
Important Notes Table 3: Fabric Watch Default Settings (Continued) Class Class Area name Description Default Settings Loss of signal count Monitors number of signal loss errors Primitive sequence protocol error Monitors number of primitive sequence errors Invalid transmission word Monitors number of invalid words transmitted Invalid CRC count Monitors number of CRC errors State changes Monitors state changes Threshold Setting Unit Error(s) Time Base Minute Low 1 High 8 Buffer 0 Unit Error(s) Time Base Minute Low 1 High 5 Buffer 0 Unit Error(s) Time Base Minute Low 1 High 5 Buffer 0 Unit Error(s) Time Base Minute Low 1 High 5 Buffer 0 Unit Error(s) Time Base Minute Low 1 High 15 Buffer 0 Alarm Setting Changed 0 Exceeded 0 Below 1 Above 1 In-between 0 Changed 0 Exceeded 0 Below 0 Above 1 In-between 0 Changed 0 Exceeded 0 Below 0 Above 1 In-between 0 Changed 0 Exceeded 0 Below 0 Above 1 In-between 0 Changed 0 Exceeded 0 Below 0 Above 1 In-between 0 Threshold State Informative Informative Normal Faulty Informative Informative Informative Normal Faulty Informative Informative Informative Normal Faulty Informative Informative Informative Normal Faulty Informative Informative Informative Normal Faulty Informative Fabric OS 3.1.3a Release Notes 17