HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 42
Diag-cmisa1, Diag-cmnobu
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
New Diagnostic and System Error Messages DIAG-CMISA1 Message Critical DIAG-CMISA1, 1 Probable Cause An attempt to send a CMI message from ASIC to ASIC failed. This usually indicates an ASIC failure. This message is generated by the cmitest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CMNOBU Message Critical DIAG-CMNOBUF, 1 Probable Cause Port could not get any buffers. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical 42 Fabric OS 3.1.3a Release Notes