HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 42

Diag-cmisa1, Diag-cmnobu

Page 42 highlights

New Diagnostic and System Error Messages DIAG-CMISA1 Message Critical DIAG-CMISA1, 1 Probable Cause An attempt to send a CMI message from ASIC to ASIC failed. This usually indicates an ASIC failure. This message is generated by the cmitest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CMNOBU Message Critical DIAG-CMNOBUF, 1 Probable Cause Port could not get any buffers. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical 42 Fabric OS 3.1.3a Release Notes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

New Diagnostic and System Error Messages
42
Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-CMISA1, 1
Probable Cause
An attempt to send a CMI message from ASIC to ASIC failed. This usually
indicates an ASIC failure. This message is generated by the
cmitest
command,
if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-CMNOBUF, 1
Probable Cause
Port could not get any buffers. This usually indicates an ASIC failure. This
message is generated by the
centralmemorytest
command, if problems are
found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-CMISA1