New Diagnostic and System Error Messages DIAG-CMBISRF Message Critical DIAG-CMBISRF, 1 Probable Cause ASIC central memory SRAMs did not complete the BISR within the timeout period. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CMBISRTO Message Critical DIAG-CMBISRTO, 1 The ASIC central memory SRAMs did not complete the BISR within the timeout period. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical 38 Fabric OS 3.1.3a Release Notes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

New Diagnostic and System Error Messages
38
Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-CMBISRF, 1
Probable Cause
ASIC central memory SRAMs did not complete the BISR within the timeout
period. This usually indicates an ASIC failure. This message is generated by the
centralmemorytest
command, if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-CMBISRTO, 1
The ASIC central memory SRAMs did not complete the BISR within the timeout
period. This usually indicates an ASIC failure. This message is generated by the
centralmemorytest
command.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-CMBISRF