HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 38
Diag-cmbisrf, Diag-cmbisrto
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
New Diagnostic and System Error Messages DIAG-CMBISRF Message Critical DIAG-CMBISRF, 1 Probable Cause ASIC central memory SRAMs did not complete the BISR within the timeout period. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CMBISRTO Message Critical DIAG-CMBISRTO, 1 The ASIC central memory SRAMs did not complete the BISR within the timeout period. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical 38 Fabric OS 3.1.3a Release Notes